GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors
Standard Features
6
6/2010
Table 1: Standard Features
GV2ME
GV2P
GV3P
GV7RE/GV7RS
0.1 to 32 A
Up to 20 hp @ 460 V
10 kA SCCR @ 480 V
Push Button Operator
0.1 to 30 A
Up to 15 hp @ 460 V
50 kA SCCR @ 480 V
Rotary Handle Operator
Visible Trip Indication
9 to 65 A
Up to 40 hp @ 460 V
GV3P13–GV3P32 rated
100 kA SCCR @ 480 V
GV3P40–GV3P65 rated
65 kA SCCR @ 480 V
Rotary Handle
25 to 220 A
Up to 150 hp @ 460 V
25 kA SCCR @ 480 V
Toggle Operator
Protection Thermal-magnetic (overload relays are bimetallic—Class 10) Solid-state overload relay—
magnetic short circuit (Class 10)
Mounting Clip-on mounting on 35 mm
DIN rail. Unclips without the
use of a tool.
Panel mounts using a metal
adapter plate.
Clip-on mounting on 35 mm
DIN rail. Unclips without the
use of a tool.
Panel mounts directly.
Clip-on mounting on 35 mm
DIN rail. Unclips without the
use of a tool.
Panel mounts directly.
Panel mounts directly
Connection Screw terminals using cross-head, captive screws. Cross-head
screws used for connections on GV2 starters and their add-on
blocks.
Uses an Allen wrench. Clip-on connectors
(sold separately)
Marking Using the marker holder supplied with each unit.
Trip test Using a fine-blade screwdriver on the front face of the product.
Signaling on the front face
Manual control
device
On or Off state On or Off state
Trip on overload,
short circuit, undervoltage,
or shunt trip.
On or Off state
Trip on overload,
short circuit, undervoltage,
or shunt trip.
On or Off state
Mechanical
flag indicator
Trips on short circuit Trips on short circuit Trip on overload or
short circuit
Padlocking Padlocks in the Off position using the system incorporated into the manual control device.
(Padlocks are supplied by the customer.)
Padlockable when used with a
door-mounted rotary handle or
with a separate locking device
Tamper-proof
current dial
The thermal-current setting dial is
covered by a transparent cover,
which can be sealed.
——
Accessories
Front-mounting
accessories
Instantaneous contact blocks—either N.C., N.O., N.O. + N.O., or N.O. + N.C.—which do not increase
the width of the product.
Front accessible,
internally mounted:
Auxiliary contacts
Trip indication contacts
Shunt trip
Undervoltage trip
Rotary Handles
Side-mounting
accessories
(snap onto the
starters without
the use of a tool)
On the left side, contact blocks which provide the following:
N.O. + N.O. or N.O. + N.C. instantaneous contacts
N.O. or N.C. trip signaling contact incorporating a mechanical flag indicator and an N.O. or N.C.
instantaneous contact
C/O magnetic trip signaling contact, associated with a mechanical flag indicator, used for reset.
On the right side:
Shunt trip or undervoltage trip
Other
accessories
Combination block for use
with TeSys
®
contactor
Bus bars and connectors
Visible isolation block,
mounting on the incoming
terminals of the device
Door interlock mechanism
Selection Page 38 Page 38 Page 38 Page 39