Brochure

GV2, GV3, and GV7 Manual Motor Starters, Controllers, and Protectors
Specifications and Operating Curves
21
6/2010
© 2001–2010 Schneider Electric
All Rights Reserved
GV3 Specifications
Table 21: Environment
Conforming to standards
IEC, NF C, BS, IEC, VDE
Approvals
ASE, CSA, UL, LROS, ÖVE
UL File Number
File E164864, CCN NLRV
CSA File Number
File LR 81630, Class 3211 05
Protective treatment
“TC”
Degree of protection
Conforming to IEC 60529 Open GV3P: IP20
Shock resistance
Conforming to IEC 68-2-27
On: 15 gn - 11 ms
Off: 30 gn - 11 ms
Vibration resistance
Conforming to IEC 68-2-6 4 gn (5...300 Hz)
Ambient air temperature
Storage -40 to +176 °F (-40 to +80 °C)
Operation Open: –4 to +140 °F (–20 to +60 °C); Enclosed: –4 to +104 °F (–20 to +40 °C)
Temperature compensation
Conforming to IEC 60157-1 Open: –4 to +140 °F (–20 to +60 °C); Enclosed: –4 to +104 °F (–20 to +40 °C)
Flame resistance
Conforming to IEC 60695-2-1 Conforms for 1760 °F (960 °C)
Maximum operating altitude
Without derating 9843 ft. (3000 m)
Table 22: Technical Characteristics, GV3P13–65
Type GV3P13–65
Operating position
Wiring
Number of conductors and c.s.a.
Mininum Maximum
Solid cable
1 x 16–2 AWG 2 x 1 mm
2
1 x 16–4 AWG + 1 x 2 AWG 1 x 25 mm
2
and 1 x 35 mm
2
Flexible cable without cable end
Flexible cable with cable end
Tightening torque
44.25 lb-in 5 N•m
44.25 lb-in for 25 mm
2
70.81 lb-in for 35 mm
2
5 N•m for 25 mm
2
8 N•m for 35 mm
2
90°
90°
90°
90°
Table 23: Technical Characteristics, GV3P13–P65
Type GV3P13–P65
Rated insulation voltage (UI)
Conforming to IEC 60947-2 690 V
Conforming to CSA C 22.2 No. 14 and UL 508 600 (B600) V
Maximum conventional rated
thermal current (lth)
Conforming to IEC 60947-4-1 65 A
Mechanical life (varies with conditions)
50,000 close–open operations
Electrical life
AC-3 duty 50,000 operating cycles
Maximum operating rate
25 operating cycles/h
Sensitivity to phase failure
Conforming to IEC 60947-4-1 Sec 7-2-1-5-2