Product Overview

Table Of Contents
21
Consult the Schneider Electric Digest for more product selection options and information.
Accessories for disconnects: VLS
VLS handle
Recessed red/yellow selector handle VLSH1S5R
Protruding red/yellow selector handle VLSH2S5R
Protruding red/yellow selector handle for 16–40 A door mount VLSH2H5R
Defeatable protruding red/yellow selector handle for 16–40 A door mount VLSH2H5RD
Recessed black selector handle VLSH1S5B
Protruding black selector handle VLSH2S5B
Defeatable protruding black selector handle for 16-40 A door mount VLSH2H5BD
VLS shaft
11.8-inch shaft VLSS3005
19.7-inch shaft VLSS5005
VLS contact accessories
Add-on fourth pole for VLS3P016R1 to 040R1 VLS1P040R1S
Add-on fourth pole for VLS3P063R1 VLS1P063R1S
Add-on fourth pole for VLS3P063D1 VLS1P063D2S
Early-make add-on fourth pole for VLS3P016R1 to 040R1 VLS1P040R1E
1 NO 1 NC side mount contact for VLS3P…R1 VLSA11RS
1 NO 1 NC side mount contact for VLS3P…D1 VLSA11DS
VLS fuse holder Add-on class CC fuse holder for VLS3p016R1 to 032R1 VLSFH1UL
TeSys™ motor control and protection solutions
Motor disconnects
`
Motor HP 460 V 1/2 3/4 1 1-1/2 2 3 5 7-1/2 10
Full load current
(NEC Table 430.250)
1.1 A 1.6 A 2.1 A 3 A 3.4 A 4.8 A 7.6 A 11 A 14 A
Open disconnect
VLS3P016R1 VLS3P016R1 VLS3P016R1 VLS3P016R1 VLS3P016R1 VLS3P016R1 VLS3P016R1 VLS3P016R1
VLS3P016R1
Ampacity 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A
SCCR 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA
Open disconnect—
door mount
VLS3P016D1 VLS3P016D1 VLS3P016D1 VLS3P016D1 VLS3P016D1 VLS3P016D1 VLS3P016D1 VLS3P016D1
VLS3P016D1
Ampacity 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A 16 A
SCCR
5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA 5 kA
Enclosed 4X disconnect
MD3304X MD3304X MD3304X MD3304X MD3304X MD3304X MD3304X MD3304X MD3304X
Ampacity 30 A 30 A 30 A 30 A 30 A 30 A 30 A 30 A 30 A
SCCR (max fuse
class/size)
65 kA
(J 30 A)
65 kA
(J 30 A)
65 kA
(J 30 A)
65 kA
(J 30 A)
65 kA
(J 30 A)
65 kA
(J 30 A)
65 kA
(J 30 A)
65 kA
(J 30 A)
65 kA
(J 30 A)
Circuit
breakers
Motor
circuit
protectors
Fusible
discon-
nects
Non-fused
discon-
nects
Fuse
holders
Manual
motor
protectors
Contactors
Overload
relays
Motor
starters
Combination
motor
controllers
Range name
PPB, Multi 9
TeSys BV4 TeSys GS
TeSys VLS,
MD
TeSys DF
TeSys GV TeSys D, F TeSys D TeSys H TeSys U
Product reference prefix
B, M9 BV4 GS VLS, MD DF GV LC LR LZ LU
Motor starter structure - 4 functions:
Disconnect
Short-circuit protection
(1)
(2)
(2)
Motor controller
Overload protection
Notes: (1) When used as a Type D combination motor controller. (2) When used as a Type E or F combination motor controller.