Instructions

Bulletin No. 65013-008-71A Tank Float Switch
April 2000 Class 9037 Type EG
3
© 1985–2000 Schneider Electric All Rights Reserved
Table 4: Rod Kits for Class 9037, Type EG-9 and EG-13 Float Position 2
Class
9049
Rod
Kits
A
[2]
F
[2]
Water Level
Change
EG-9
[1]
EG-13
[1]
R
[2]
H
[2]
Min Max Min Max Min Max Min Max
ER-1 1-3/4 7-1/2 1 3 3-1/16 5-1/16 5-1/4 7-1/4 2-3/4 4-1/4
ER-2 2-1/2 8-1/4 1 3-1/2 3-1/16 5-9/16 5-3/4 8-1/4 2-3/4 5-1/4
ER-3 3-1/4 9 1 4 3-1/16 6-1/16 6 9 3 6
ER-5 5-1/4 11 1 5 3-1/16 7-1/16 6-3/4 10-3/4 3-3/4 7-3/4
ER-7 7-1/4 13 1 6 3-1/16 8-1/16 7-3/4 12-3/4 4-3/4 9
ER-12 12-1/4 18 1 8-1/2 3-1/16 10-9/16 10-1/4 17-3/4 7-1/4 12-1/4
[1]
Dimensions are in inches.
[2]
Letters refer to Figure 2.
Table 5: Rod Kits for Class 9037, Type EG-9 and EG-13 Float Position 3
Class
9049
Rod
Kits
H
[2]
f1 or f2
[2]
F
[2]
Water Level
Change
R
[2]
EG-9
[1]
EG-13
[1]
Min Max Min Max Min Max
ER-1 1-3/4 9 11 2-3/4 4-1/2 5-1/2 9 2-1/4 5-3/4
ER-2 2-1/2 9-3/4 11-3/4 2-3/4 4-1/2 5-1/2 9 2-1/4 5-3/4
ER-3 3-1/4 10-1/2 12-1/2 3 5 6 10 2-3/4 6-3/4
ER-5 5-1/4 12-1/2 14-1/2 3-1/2 6 7 12 3-3/4 8-3/4
ER-7 7-1/4 14-1/2 16-1/2 3-3/4 7 7-1/2 14 4-1/4 10-3/4
ER-12 12-1/4 19-1/2 21-1/2 4-1/2 9-1/2 8-3/4 19 5-1/2 15-3/4
[1]
Dimensions are in inches.
[2]
Letters refer to Figure 3.
P
R
4-1/2 in.
H
F
A min
1-13/16 in.
3-5/8 in.
P = (post clearance dimension) is 2-5/8 in. for
short post models. On long post models (types
EG-9 and EG-13) this distance is 4-11/16 in.
Figure 2: Float Position 2 - Vertical
mounting, standard operation;
contacts close as liquid level
falls.
H
P
R
f2
f1
F
P = (post clearance dimension) is 2-5/8 in. for
short post models. On long post models (types
EG-9 and EG-13) this distance is 4-11/16 in.
Figure 3: Float Position 3 - Horizontal
mounting. Standard or sump
operation depends on the
position of the switch. To
reverse operation, turn the
control through 180° around the
horizontal center line.