User Guide
Table Of Contents
- Altivar Machine ATV320
- Table of Contents
- Safety Information
- About the Book
- Introduction to Device Conversion Function
- Control Block Terminals
- Functions Compatibilities
- Applicative Functions
- Reverse
- Reverse Inhibition
- Speed Loop Parameters
- Macro-Configurations
- I/O Multi-Assignments
- 2/3 Wires Control
- Freewheel Stop
- Fast Stop
- Ramp Types
- Ramp Switching
- Ramp Auto-Adaptation
- DC Injection Braking
- Reference Switching
- Separate Mode (Command & Reference)
- Reference Operation
- Jog
- Preset Speeds
- Brake Control Sequence
- +/- Speed
- 2nd Current Limitation
- Jump Frequency
- PID Regulator
- Internal PID reference
- Preset PID Reference
- Sleep / Wake-Up
- Catch On the Fly
- Automatic Restart
- Multi-Motors / Multi-Configurations
Function Compatibilities
32
QGH39563 02/2017
2
nd
Current Limitation
Overview
This function is available in both ATV312 and ATV320 drives.
Device Conversion
Conversion from an ATV312 configuration into ATV320 configuration is supported for this function.
For more information about 2
nd
Current Limitation, refer to the ATV320 Programming Manual (
NVE41295
).
Jump Frequency
Overview
This function is available in both ATV312 and ATV320 drives.
ATV320 offers additional parameters for this function.
Device Conversion
Conversion from an ATV312 configuration into ATV320 configuration is supported for this function.
For more information about Jump Frequency, refer to the ATV320 Programming Manual (
NVE41295
).
PID Regulator
Overview
This function is available in both ATV312 and ATV320 drives.
ATV312 offers a PI Regulator.
ATV320 offers a PID Regulator.
Device Conversion
Conversion from an ATV312 configuration into ATV320 configuration is not supported for this function.
The parameters related to this function are set to factory setting values and needs to be adjusted
depending on the application.
For more information about PID Regulator, refer to the ATV320 Programming Manual (
NVE41295
).
Internal PID reference
Overview
This function is available in both ATV312 and ATV320 drives but configuration of this function is not the
same.
Device Conversion
Conversion from an ATV312 configuration into ATV320 configuration is not supported for this function.
The parameters related to this function are set to factory setting values and needs to be adjusted
depending on the application.
For more information about Internal PID reference, refer to the ATV320 Programming Manual
(
NVE41295
).