Brochure
26-30
© 2019 Schneider Electric
All Rights Reserved
Enclosed Soft Starter AC Soft Starter Products
schneider-electric.us
Panel Mounted / Open AC Drive Solutions
Enclosed Altistart™ 22 Motor Controllers
Enclosed Altistart 22 (ATS22) solid-state combination motor controllers are a pre-
engineered, integrated solution for reduced voltage starting and soft stopping of standard
three-phase asynchronous induction (squirrel cage) motors. The Enclosed 22 controllers
consist of a disconnect means and an ATS22 softstarter in a stand-alone enclosure.
Enclosed 22 controllers integrate the ATS22 softstart technology into a combination
package for application requirements up to 400 hp at 460 V.
•
3–150 hp, 208 V
•
5–200 hp, 230 V
•
10–400 hp, 460 V
•
15–500 hp, 575V
Table 26.33: Enclosed Altistart 22 Catalog Number Description
Field
Digit
Characteristic
Description
— — Controller Class
8638 = Fused Disconnect [1]
8639 = Circuit Breaker Disconnect
01 1–3
Controller Style
22F = Altistart 22 with Class J Fuse Clips and Molded Case Switch [1]
22T = Altistart 22 with PowerPact Motor Circuit Protector
22U = Altistart 22 with PowerPact Thermal-Magnetic Circuit Breaker
02 4
Horsepower
A = 3 hp
B = 5 hp
C = 7.5 hp
D = 10 hp
E = 15 hp
F = 20 hp
G = 25 hp
H = 30 hp
J = 40 hp
K = 50 hp
L = 60 hp
M = 75 hp
N = 100 hp
P = 125 hp
Q = 150 hp
R=200 hp
S= 250 hp
T= 300 hp
U=350 hp
W= 400 hp
X= 500 hp
03 5
Enclosure Type
G = UL Type 1 General Purpose
A = UL Type 12K Industrial Use, Dust-Tight/Drip-Tight
H = UL Type 3R Outdoor Use
04 6
Voltage
2 = 208 Vac
3 = 230 Vac
4 = 460 Vac
5 = 575 Vac
05 7 Power Circuit
B = Basic Shunt Trip
S = Full-Featured Shunt Trip
N = Non-Reversing Isolation
R = Reversing Isolation
Y = Integral Full-Voltage Bypass
06 8–10
Control Options [2] [3]
A06 = Start-Stop Push Buttons
B06 = Forward-Off-Reverse
C06 = Hand-Off-Auto (HOA) Selector Switch
D06 = Stop-Run Selector Switch
E06 = Hand-Auto Selector Switch/Start-Stop Push Buttons
07 11–13
Pilot Device Options
[2] [3]
A07 = Run Light (Red), Off Light (Green)
B07 = Push-to-Test Run Light (Red), Push-to-Test Off Light (Green)
C07 = Run Light (Red), Off Light (Green), Tripped Light/Reset (Yellow)
D07 = PTT Run Light (Red), PTT Off Light (Green), Tripped Light/
Reset (Yellow)
08 14–16
Metering Options B08 = Elapsed Run Time Meter [3]
09 17–19
Miscellaneous
Options
A10 = Floor Mounting Kit [4]
B10 = Additional 150 VA [5]
C10 = Power-Up On Delay Relay[6]
D10 = Emergency Stop Push Button [5]
E10 = cUL Label [7]
F10 = Auxiliary Run Mode Contacts
G10 = Auxiliary FB Bypass Contacts [8]
H10 = Auxiliary Auto Mode Contacts [9]
J10 = Auxiliary Trip Indication Contacts
L10 = ID Engraved Nameplate [5]
M10 = 10 Spare Terminal Blocks [5]
P10 = Permanent Wire Markers [5]
R10 = MOV-Surge Arrestor [5]
U10 = Omit Door-Mounted Keypad Display [10]
X10 = 50 °C Operation
Y10 = Seismic qualification label
Z10 = Service Entrance Rating [7] [11]
910 = American Recovery and Reinvestment Act (ARRA) Option
Table 26.34: Enclosed Altistart 22 Catalog Number Example:
863922UCG4BA06A07
Field
— 1 2 3 4 5 6 7
8639 22U C G 4 B A06 A07
Controller
Class
PowerPact™
Thermal- Magnetic
Circuit Breaker
7.5 hp
Type 1
General
Purpose
460
Vac
Basic
Shunt
Trip
Start-Stop Push
Button
Run Light
(Red), Off
Light (Green
26
AC DRIVES AND SOFT STARTERS
[1] This option is not selectable with power circuit option B05.
[2] Select only one option.
[3] To omit, do not include a selection in the catalog number.
[4] This option is available only for enclosure size D.
[5] This option is not selectable with power circuit option B05
[6] This option is not selectable with power circuit option B05. This option is valid only with the following control options: C06, D06, or E06.
[7] Options E10 and Z10 cannot be used together.
[8] This option is not selectable with power circuit option B05. The contacts are available only when power circuit option Y05 is selected.
[9] The contacts are not available when power circuit option R05 is selected. This option is valid only with the following control options: C06, D06, or E06.
[10] If you select option U10, you must separately order the remote keypad (VW3G22101) and cable (VW3A1104R30) to commission the softstarter. Refer to the ATS22 User Manual,
BBV51330, for serial communication programming and control capabilities.
[11] Options E10 and Z10 cannot be ordered together.