Brochure
© 2019 Schneider Electric
All Rights Reserved
26-25
schneider-electric.us
Altivar
TM
Process 930/950 AC Drives Selection Tables
Panel Mounted / Open AC Drive Solutions
Altivar™ Process 930/950
Altivar Process 930
Table 26.21: Altivar Process 930/950 Selection
Input Line
Voltage
Normal Duty [38] Heavy Duty [39]
Catalog Number
Three-phase Motor
Power [40]
Continu-
ous
Output
Current
[41]
Three-phase Motor
Power [40]
Continuous
Output
Current [41]
HP kW A HP kW A
208/240
Vac
Three
Phase
1 0.75 4.6 0.5 0.37 3.3 ATV930U07M3
2 1.5 8 1 0.75 4.6 ATV930U15M3
3 2.2 11.2 2 1.5 8 ATV930U22M3
4 3.0 13.7 3 2.2 11.2 ATV930U30M3
5 4.0 18.7 4 3 13.7 ATV930U40M3
7.5 5.5 25.4 5 4 18.7 ATV930U55M3
10 7.5 32.7 7.5 5.5 25.4 ATV930U75M3
15 11 46.8 10 7.5 32.7 ATV930D11M3
20 15 63.4 15 11 46.8 ATV930D15M3
25 18.5 78.4 20 15 63.4 ATV930D18M3
30 22 92.6 25 18.5 78.4 ATV930D22M3
40 30 123 30 22 92.6 ATV930D30M3
50 37 149 40 30 123 ATV930D37M3
60 45 176 50 37 149 ATV930D45M3
75 55 211 60 45 176 ATV930D55M3
100 75 282 75 55 211 ATV930D75M3
400/480
Vac
Three
Phase
1 0.75 2.2 0.5 0.37 1.5
ATV930U07N4
ATV950U07N4U
2 1.5 4 1 0.75 2.2
ATV930U15N4
ATV950U15N4U
3 2.2 5.6 2 1.5 4
ATV930U22N4
ATV950U22N4U
4 3 7.2 3 2.2 5.6
ATV930U30N4
ATV950U30N4U
5 4 9.3 4 3 7.2
ATV930U40N4
ATV950U40N4U
7.5 5.5 12.7 5 4 9.3
ATV930U55N4
ATV950U55N4U
10 7.5 16.5 7.5 5.5 12.7
ATV930U75N4
ATV950U75N4U
15 11 23.5 10 7.5 16.5
ATV930D11N4
ATV950D11N4U
20 15 31.7 15 11 23.5
ATV930D15N4
ATV950D15N4U
25 18.5 39.2 20 15 31.7
ATV930D18N4
ATV950D18N4U
30 22 46.3 25 18.5 39.2
ATV930D22N4
ATV950D22N4U
40 30 61.5 30 22 46.3
ATV930D30N4
ATV950D30N4U
50 37 74.5 40 30 61.5
ATV930D37N4
ATV950D45N4U
60 45 88 50 37 74.5
ATV930D45N4
ATV950D55N4U
75 55 106 60 45 88
ATV930D55N4
ATV950D55N4U
100 75 145 75 55 106
ATV930D75N4
ATV950D75N4U
125 90 173 100 75 145
ATV930D90N4
ATV950D90N4U
150 110 211 125 90 173 ATV930C11N4C
200 130 250 150 110 180 ATV930C13N4C
250 160 302 200 132 240 ATV930C16N4C
250 160 302 200 132 240 ATV930C16N4
350 220 324 250 160 246 ATV930C22N4
400 250 366 300 220 301 ATV930C25N4C
450 310 461 400 250 375 ATV930C31N4C
690 Vac
Three
Phase
3 2.2 3.1 2 1.5 2.4 ATV930U22Y6
— 3 4.2 3 2.2 3.1 ATV930U30Y6
5 4 5.4 — 3 4.2 ATV930U40Y6
7.5 5.5 7.2 5 4 5.4 ATV930U55Y6
10 7.5 9.5 7.5 5.5 7.2 ATV930U75Y6
15 11 13.5 10 7.5 9.5 ATV930D11Y6
20 15 18 15 11 13.5 ATV930D15Y6
25 18 24 20 15 18 ATV930D18Y6
30 22 29 25 18 24 ATV930D22Y6
40 30 34 30 22 29 ATV930D30Y6
50 37 45 40 30 34 ATV930D37Y6
60 45 55 50 37 45 ATV930D45Y6
75 55 66 60 45 55 ATV930D55Y6
100 75 83 75 55 66 ATV930D75Y6
125 90 108 100 75 83 ATV930D90Y6
26
AC DRIVES AND SOFT STARTERS
[38] Normal duty applications requiring an overload up to 120% for 60 seconds. Typical for variable torque loads.
[39] Heavy duty applications requiring an overload up to 150% for 60 seconds. Typical for constant torque loads.
[40] These values are given for a nominal switching frequency of 4 kHz up to ATV930D45N4, or 2.5 kHz for ATV930D55N4...D90N4 for use in continuous operation. The switching frequency is
adjustable from 1...16 kHz for all ratings. Above 2.5 or 4 kHz (depending on the rating), the drive will automatically reduce the switching frequency in the event of an excessive temperature
rise. For continuous operation above the nominal switching frequency, derate the nominal drive current (see the derating curves on our website www.schneider- electric.com).
[41] Typical value for the indicated motor power and for the maximum prospective line Isc.