Brochure
© 2019 Schneider Electric
All Rights Reserved
22-9
schneider-electric.us
XMLK Pressure Transmitters
Electronic Pressure Sensors
Refer to Catalog 9014CT0201
XMLK Pressure Transmitters
XMLK•••••C
DIN 43650A Connector
XMLK•••••D
M12 Connector
XMLK•••••P
Metri-Pack Connector
Type XMLK pressure transmitters are characterized by their ceramic pressure-
measuring cell. The deformation caused by the pressure is transmitted to the resistors of
a Wheatstone bridge silk-screened on the ceramic. The change in resistance is then
processed by the integrated electronics to provide an analog output signal.
Table 22.26: Environmental Specifications
Enclosure Rating IP65 conforming to IEC/EN 60529, NEMA 4
Ambient Air
Temperature
For Operation 0 to +80 °C (32 to 176 °F)
For Storage –25 to +85 °C (13 to 185 °F)
Precision (Resolution)
Combined sum of linearity, hysteresis, and repeat accuracy <± 0.5%
of the measuring range
Setting tolerance of zero point and measuring range limit < ± 1% of
the measuring range
Repeat Accuracy ± 0.3% of the measuring range
Current Consumption
4–20 mA: < 20 mA
0–10 V: < 6 mA
Rated Supply Voltage
24 Vdc
Voltage Limits
4–20 mA: 8–33 Vdc
0–10 V: 16.2–33 Vdc
Fluids or Products Controlled
Air, fresh water (0 to +80 °C / 32 to 176 °F)
Materials in Contact with Fluid
Steel, type AISI 303 (stainless steel)
nitrile (NBR)
Output Response Time
< 2 ms
Table 22.27: Interpretation of the Catalog Number
Units Without Display
Rated Pressure
Unit of
Pressure
O-Ring
Electrical Connection
Output
Fluid Connection
Bulk
Pack
Code
psi
bar
XMLK 100 P 2 D 2 3 TQ
36 mm (1.42 in.)
diameter
006 0–6 B: bar
2: NBR
(Nitrile)
C: DIN 43650A
2: Analog, 4–20 mA 1: G 1/4 A (male)
010 0–10
P: psi
D: M12
7: Analog, 0-10 V 3: 1/4"-18 NPT (male)
016 0–16 P: Metri-Pack
025 0–25
100 0–100
150 0–150
200 0–200
300 0–300
NOTE: Use this table only to interpret the catalog number. Some combinations are
not available.
Table 22.28: Selection
Rated Pressure Range
Catalog Number [9]
4–20 mA Analog Output 0–10 Vdc Analog Output
DIN M12 Metri-Pack DIN M12 Metri-Pack
Bar Version, G 1/4 A Male Fluid Connector
0–6 bar (0–87 psi)
XMLK006B2C21 XMLK006B2D21 — XMLK006B2C71 XMLK006B2D71 —
0–10 bar (0–145 psi)
XMLK010B2C21 XMLK010B2D21 — XMLK010B2C71 XMLK010B2D71 —
0–16 bar (0–232 psi)
XMLK016B2C21 XMLK016B2D21 — XMLK016B2C71 XMLK016B2D71 —
0–25 bar (0–362.5 psi)
XMLK025B2C21 XMLK025B2D21 — XMLK025B2C71 XMLK025B2D71 —
PSI Version, 1/4"-18 NPT Male Fluid Connector
0–100 psi (0–6.9 bar)
XMLK100P2C23 XMLK100P2D23 XMLK100P2P23 XMLK100P2C73 XMLK100P2D73 XMLK100P2P73
0–150 psi (0–10.3 bar)
XMLK150P2C23 XMLK150P2D23 XMLK150P2P23 XMLK150P2C73 XMLK150P2D73 XMLK150P2P73
0–200 psi (0–13.8 bar)
XMLK200P2C23 XMLK200P2D23 XMLK200P2P23 XMLK200P2C73 XMLK200P2D73 XMLK200P2P73
0–300 psi (0–.20.7 bar)
XMLK300P2C23 XMLK300P2D23 XMLK300P2P23 XMLK300P2C73 XMLK300P2D73 XMLK300P2P73
Table 22.29: Wiring Configurations (M12)
Output
Pin 1 Pin 3 Pin 4
Analog, 4–20 mA + Power supply Output
—
Analog, 0–10 Vdc + Power supply Output
Ground
Solid State, NPN
+ Power supply
Ground
Output
Solid State, PNP
+ Power supply
Ground
Output
UL E164865
CCN NKPZ
LR 44087
Class 3211-03
For wiring diagrams, refer to page 22-5.
22
PRESSURE, VACUUM, AND FLOAT
SWITCHES
[9] For a bulk package (25 units), add TQ to the end of the catalog number. The minimum order quantity is 50 units (two bulk packs). When ordering, specify the individual number of units, not
the number of bulk packs. Minimum order quantity for factory ordered individual items (non-stock) is 50 pieces.