Brochure
22-4
© 2019 Schneider Electric
All Rights Reserved
Electronic Pressure Sensors XMLG Pressure Transmitters
schneider-electric.us
Refer to Catalog 9014CT0201
22
PRESSURE, VACUUM, AND FLOAT
SWITCHES
XMLG Pressure Transmitters
XMLG●●●D
M12 Connector
XMLG●●●Q
Quick Connect
XMLG pressure transmitters are characterized by their ceramic pressure-measuring cell.
The deformation caused by the pressure is transmitted to the resistors of a Wheatstone
bridge silk-screened on the ceramic. The change in resistance is then processed by the
integrated electronics, providing an analog output signal.
Table 22.1: Specifications
Enclosure Rating IP66, IP67 conforming to IEC/EN 60529, NEMA 4
Ambient Temperature (Operation) -15 to +85 °C (+5 to +185 °F)
Media Temperature -15 to +125 °C (+5 to +257 °F)
Precision (Linearity, Repeat Accuracy,
Hysteresis)
Transmitters: <0.3%
Repeat Accuracy (PNP/NPN output) 0.1% of the measuring range
Current Consumption
Transmitters: < 20 mA
Maximum Load Current Transmitters: < 20mA
Rated Voltage
12/24 V for transmitters
Voltage Limits
24 V for transmitters
Fluids Controlled
Hydraulic oils, air, fresh/sea water, corrosive fluids from -15 to +125
°C (+5 to +257 °F)
Materials in Contact with Fluid
Ceramic Al
2
O
3
, stainless steel type AISI 303, Viton
®
FPM, PPS
(leakage protection for P> 40 bar)
Output Response Time
< 2 ms
Table 22.2: Interpretation of the Catalog Number (example: XMLG100D23TQ)
XMLG 100 D 2 3
TQ
Units without Display, 22.8
mm diameter
Rated Pressure Range
Electrical
Connection
Output
Fluid Connection Bulk Pack
Code
psi
bar
M01 –14.5 to 0 –1 to 0 D: M12
1: DC Analog, 4–20 mA, shunt calibration
1: G 1/4 A
(BSP male)
001 0 to 14.5 0 to 1
Q: Integrated
quick connect
2: Analog, 4–20 mA
006 0 to 87.0 0 to 6
7: Analog, 0–10 V (bulk packs only)
3: 1/4" NPT male
010 0 to 145 0 to 10
11: DC Analog, 0–10 V shunt calibration
7: 7/16-20 UNF male
016 0 to 232.1 0 to 16
025 0 to 362.5 0 to 25
100 0 to 1450 0 to 100
160 0 to 2329.6 0 to 160
250 0 to 3625 0 to 250
400 0 to 5800 0 to 400
NOTE: Use this table only to interpret the catalog number. Some combinations are
not available.
Table 22.3: Selection
Rated Pressure Range
Fluid Connection Electrical Connection
Catalog Number[1][2]
Analog Output,
4–20 mA
Analog Output,
0–10 Vdc
-14.5 to 0 psi
-1 to 0 bar
1/4" NPT Male M12
XMLGM01D23 XMLGM01D73
0 to 14.5 psi
0 to 1 bar XMLG001D23 XMLG001D73
0 to 87 psi
0 to 6 bar XMLG006D23 XMLG006D73
0 to 145 psi
0 to 10 bar XMLG010D23 XMLG010D73
0 to 232 psi
0 to 16 bar XMLG016D23 XMLG016D73
0 to 362.5 psi
0 to 25 bar XMLG025D23 XMLG025D73
0 to 1450 psi
0 to 100 bar XMLG100D23 XMLG100D73
0 to 2320 psi
0 to 160 bar XMLG160D23 XMLG160D73
0 to 3625 psi
0 to 250 bar XMLG250D23 XMLG250D73
0 to 5800 psi
0 to 400 bar XMLG400D23 XMLG400D73
NOTE: For units with a solid-state output, the settings must be specified for each
order.
Table 22.4: Wiring Configurations (M12)
Output
Pin 1 Pin 3 Pin 4
Analog, 4–20 mA + Power supply Output
—
Analog, 0–10 Vdc + Power supply Output
Ground
Solid State, NPN
+ Power supply
Ground
Output
Solid State, PNP
+ Power supply
Ground
Output
UL E164865
CCN NKPZ
LR 44087
Class 3211-03
For wiring diagrams, refer to page 22-5.
[1] For devices with a switch output or 0–10 Vdc analog output, contact the Sensor Competency Center at 1-800-435-2121.
[2] For a bulk package (25 units), add TQ to the end of the catalog number. The minimum order quantity is 50 units (two bulk packs). When ordering, specify the individual number of units, NOT
the number of bulk packs. Minimum order quantity for factory ordered individual items (non-stock) is 50 pieces.