Brochure
22-26
© 2019 Schneider Electric
All Rights Reserved
Commercial Pressure Switches Type G—Pumptrol Pressure Switch
schneider-electric.us
Class 9013 / Refer to Catalog 9013CT9701
22
PRESSURE, VACUUM, AND FLOAT
SWITCHES
Type G Pressure Switch Selection and Features
™
Shown with Form X
File E12158
CCN NKPZ
File 25490
File 26817
Haz. Loc.
File E12443 Haz Loc
CCN NOWT
Table 22.82: Pressure Codes
Code
Pressure Setting (Close-Open), psi
J20 20–40
J21 30–50
J23
40–20 (reverse action)
J24 40–60
J25 60–80
J26 70–90
J28 70–100
J29 75–100
J30 80–100
J31 90–120
J50 135–175
J51
100–80 (reverse action)
J53 100–125
J54 110–125
J56 110–150
J57 120–150
J58 125–150
J60 125–175
J61 130–175
J62 140–175
J63 145–175
J64
150–120 (reverse action)
J65 215–250
J99
Specify the required setting
Table 22.83: Special Features and Modifications
Description Form
3-Way Lever (On-Auto-Off) E
One Normally Open / One Normally Closed Contact H
Pulsation Plug P
Reverse Action R
Slip-On Connectors (Load Side Terminals Only) U
Slip-On Connectors (Line and Load Terminals) U2
Two-Way Pressure Release Valve X
¼" Male Pipe Thread on Pressure Connection Z
½"-14 NPT External, ¼"-18 NPT Internal Z16
Class 9013 Type G Pumptrol pressure switches are designed to control electrically
driven water pumps and air compressors. These devices cover higher electrical ratings
for directly controlling motors in pump and compressor applications.
•
Contacts open on pressure rise.
•
Diaphragm actuated.
•
For electrical ratings, see Table 22.74.
For repair parts kits, see page 22-34.
Table 22.84: Selection Tables
Cut-out
Range
(psig)
Approximate
Adjustable
Differential
(psig)
Cut-in
Range
(psig)
Enclosure Poles
NPSF Internal
Pressure
Connection
Catalog No.
10–35 4–8 5.5–30.5
NEMA 1 (General Purpose)
2 1/4 9013GMG2
20–80 15–30 5–60
NEMA 3R [13] (Rainproof)
2 1/4 9013GSB2
20–80 15–30 5–60
NEMA 1 (General Purpose)
2
1/8 9013GSG1
1/4 9013GSG2
3/8 9013GSG3
20–80 20–40 5–50
NEMA 7 & 9
(Hazardous Locations)
2
1/8 9013GSR1
1/4 9013GSR2
3/8 9013GSR3
NEMA 4 (Watertight)
1/8 9013GSW1
1/4 9013GSW2
3/8 9013GSW3
65–200 20–40 40–170
NEMA 3R [13] (Rainproof)
2 1/4 9013GHB2
65–200 20–40 40–170
NEMA 1 (General Purpose)
2
1/8 9013GHG1
1/4 9013GHG2
3/8 9013GHG3
65–200 30–50 35–150
NEMA 7 & 9
(Hazardous Locations)
2
1/8 9013GHR1
1/4 9013GHR2
3/8 9013GHR3
NEMA 4 (Watertight)
1/8 9013GHW1
1/4 9013GHW2
3/8 9013GHW3
80–250 25–45 32–215
NEMA 3R [13] (Rainproof)
2 1/4 9013GHB5
80–250 24–45 32–215
NEMA 1 (General Purpose)
2
1/8 9013GHG4
1/4 9013GHG5
3/8 9013GHG6
80–250 40–60 30–190
NEMA 7 & 9
(Hazardous Locations)
2
1/8 9013GHR4
1/4 9013GHR5
3/8 9013GHR6
NEMA 4 (Watertight)
1/8 9013GHW4
1/4 9013GHW5
3/8 9013GHW6
NOTE: Some product configurations are not available. Contact your Schneider
Electric representative for details.
Ordering Information
•
Specify Class 9013 Type G.
•
Select the pressure code from Table 22.82, and add the code to the end of the Type
number. Ensure that the pressure rating of the code falls within the limits of the device.
See Table 22.84.
•
To order special features, add the appropriate Form letter to the Class and Type.
Arrange Form letters in alphabetical order when ordering more than one special
feature.
[13] Must be mounted in vertical position to maintain enclosure rating.