Brochure
22-2
© 2019 Schneider Electric
All Rights Reserved
Pressure, Vacuum, and Float Switches Selection Guide
schneider-electric.us
Class 9012 / Refer to Catalog 9012CT9701 or 9014CT0201
22
PRESSURE, VACUUM, AND FLOAT
SWITCHES
9012 Sensor Selections
Application
Electronic Electromechanical Control
Product
Family
XMLG XMLP XMEP XMLK XMLR
XMLA, B, C, D
9012G
Type of
Installation/
Application
Control circuits Control circuits
Control circuits for
mobile equipment
Control circuits
Pumping applications
Control circuits Control circuits Control circuits
Fluids
Controlled
Air, water, hydraulic
oils, corrosive fluids
Air, fresh water, most
hydraulic oils
Hydraulic oils, air, fresh
water, gas
Air, fresh water, 0 to +
80 °C (32 to 176 °F)
Air, water, hydraulic oils, corrosive fluids
Type of
Operation and
Features
Pressure/vacuum
transmitters
Analog output
4–20 mA or 0–10 V
Pressure/vacuum
transmitters
Analog output
4–20 mA, 0–10 V, 0.5–
4.5 V ratiometric
Pressure transmitters
Analog output
4–20 mA, 0–10 V, 0.5–
4.5 V ratiometric
Pressure transmitters
Analog output, 4–20
mA or
0–10 V
Pressure/vacuum
switches and
transmitters
Configurable units
with digital display
Analog output 4–20
mA, 0–10 V
Regulation between
2 trip points
(adjustable
differential)
Pressure/vacuum
switches
Detection of single
trip point
(nonadjustable
differential)
Regulation between
2 trip points
(adjustable
differential)
Pressure switches
Detection of single trip
point (nonadjustable
differential)
Regulation between 2
trip points (adjustable
differential)
2-stage
Size/Range –14.5 to 5800 psi –14.5 to 6000 psi
0–870 psi, 0–1450 psi,
0–3625 psi
0–5800 psi, 0–8700 psi
0 to 25 bar or 0 to 300
psi, depending on the
model
–14.5 to 8700 psi –14.5 to 7250 psi 0.2 to 9000 psi
Type of
Output
Analog, 4–20 mA or 0–
10 V
Analog, 4–20 mA, 0–10
V, 0.5–4.5 V
Analog, 4–20 mA, 0–10
V or 0.5–4.5 V
Analog, 4–20 mA or 0–
10 V
Analog, 4–20 mA,
0–10 V
Digital, PNP or NPN,
Snap action contacts
SPDT or DPDT
10 A continuous
Snap action contacts
SPDT or DPDT
10 A continuous
Electrical
Connection
M12 connector or
Integrated quick
connection
M12, DIN 43650,
Metri-Pack 150
connector, or 2 m PVC
cable
M12 connector (4-pin),
AMP Superseal 1.5
connector (3-pin), AMP
Junior Power Timer
connector (3-pin),
Deutsch DT04-3P
connector (3-pin)
M12, DIN 43650 A or
Metri-Pack connector
[1]
M12 connector
SAE 7/8-16 UN2A
Cable entry for Pg
13
(DIN PG13.5) cable
gland,
ISO M20, 1/2" NPT,
and 1/2" PF
1/2" -14 NPT
Cable entry 20 mm
Fluid
Connection
G 1/4" BSP internal,
1/4" NPT internal
SAE 7/16"-20 UNF
female
1/4 A male, 1/4"-18
NPT male, SAE 7/16-
20 UNF-2A male, SAE
7/16-20 UNF-2B
female
G 1/4 A DIN 3852-E
male, 1/4"-18 NPT
male
G 1/4 A (male)
conforming to ISO7 or
1/4"-18 NPT male [1]
G 1/4" BSP internal,
1/4" NPT internal
SAE 7/16"-20 UNF
female
G 1/4" BSP internal,
1/4" NPT internal
1/4"-18 NPT external
1/4" - 18 NPTF internal
7/16"-20 UNF-2B
internal
G 1/4" BSP internal
G 1/4"-19 BSP internal
Fluid
Characteris-
tics
Hydraulic oils, air, fresh
water, sea water,
corrosive fluids from
–15 to +125 °C
(+5 to +257 °F)
Fresh water
(0 to +135 °C)
Air, hydraulic oils,
refrigeration fluids
(–30 to +135 °C)
Hydraulic oils, air, fresh
water, gas (–40 to +125
°C)
Air, fresh water, 0 to +
80 °C (+32 to +176 °F)
Hydraulic oils, air,
fresh water, sea
water, corrosive
fluids from –15 to
+80 °C
(+5 to +176 °F)
Hydraulic oils, air,
fresh water, sea
water, steam,
corrosive fluids,
viscous products, 0
to +160 °C
(+32 to +320 °F)
depending on the
model
Hydraulic oils, air, fresh
water, sea water,
corrosive fluids from –26
to +120 °C (–15 to +250
°F)
depending on the model
Enclosure
Rating
IP66, IP67 conforming
to IEC/EN 60529,
NEMA 4
IP65 or IP67,
IP69K (M12
connector),
conforming to EN/IEC
60529
IP65, IP67, and IP69K
conforming to EN/IEC
60529
IP65 conforming to
IEC/EN60529, NEMA
4
IP67 conforming to
IEC/EN 60529,
NEMA 4/6/12/13
Screw terminal
models: IP66
conforming to IEC
529, NEMA 4
NEMA Type
4, 4X, 7, 9, 13
Dimensions of
Case, in. (mm)
width x height
x depth
dia. 0.90 x 2.76
(dia. 22.8 x 70.1 mm)
Ø 26 x 38 (M12)
Ø 26 x 60.5 (DIN
43650)
Ø 26 x 55 (Metri-Pack)
Ø 24 x 38.1, Ø 24 x
62.1, Ø 24 x 60.5, Ø 24
x 54, Ø 24 x 60
dia. 1.40 x 3.10
(dia. 36 x 79.5)
1.6 x 3.93 x 1.6 in.
(41 x 100 x 42 mm)
4.45 x 1.38 x 2.95 in.
(113 x 35 x 75 mm)
NEMA 4: 3.50 x 3.60
x 2.63 in. (89 x 91 x
67 mm)
NEMA 1: 2.06 x 5.03 x
2.75 in.
(52 x 128 x 70 mm)
NEMA 4: 3.50 x 3.60 x
2.63 in.
(89 x 91 x 67 mm)
Conforming to
Standards
CE, IEC/EN 60947-1,
IEC/EN 60947-5-1, EN
50081-1,
EN 50082-2,
EN 61000-6-2
CE, ROHS,
EN/IEC 61326-2-3,
NSF ANSI 61
CE, ROHS,
EN/IEC 61326-2-3,
ECE 10R-5,
ISO 13766, ISO 14982,
EN 13309
CE, IEC/EN 60947-1,
IEC/EN 60947-5-1
EN 50081-1,
EN 50082-2,
EN 61000-6-2
CE, IEC/EN 60947-
1,
IEC/EN 60947-5-1,
EN 50081,
EN 50082,
EN 61000-6-2,
EN 61000-4-2/3/4/5/
6/8/11
CE, IEC/EN 60947-
5-1,
VDE 0660-200,
UL 508,
CSA C22-2 No. 14
NEMA A600 UL508
Certifications
UL Listed,
CSA Certified
cULus conforming to
UL 61010-1 and
CSA-C22.2 no. 61010-
1, EAC, RCM
cULus conforming to
UL 61010-1, E2
conforming to UNECE
10R-5 (pending)
UL: File E97729,
CCN NKPZ
CSA: File 240515,
Class 3211-03
UL Listed,
CSA Certified
UL B300 - R300
Listed.
CSA B300 - R300,
(BV, GL, RINA,
LROS pending)
UL Listed,
CSA Certified
Catalog
Number
XMLG XMLP XMEP XMLK XMLR
XMLA, XMLB,
XMLC, XMLD
9012GA, GB, GC, GD,
GE, GF, GG, GH, GJ,
GK, GL, GM, GN, GP,
GQ, GR, GS, GT
[1] For other connections, consult the Sensor Competency Center.