Brochure

© 2019 Schneider Electric
All Rights Reserved
22-17
schneider-electric.us
Machine Tool, Type G Pressure Switches
Class 9012 / Refer to Catalog 9012CT9701
Control Circuit Rated Type G Pressure Switches
9012GAW5
NEMA 4, 4X, 13
Class 9012 single stage pressure switches are control circuit rated devices used in pneumatic or hydraulic systems on a wide variety of machine
and process applications to protect the equipment and control or monitor the system pressure.
Type G machine tool switches are available with NEMA Type 4, 4X, and 13 (IEC IP66) enclosure ratings.
The NEMA 7 and 9 devices are UL listed for use in the following hazardous locations: Class I, Divisions 1 and 2, Groups C and D; and Class II,
Divisions 1 and 2, Groups E, F, and G.
Enclosure materials are cast aluminum.
To ensure repeatability and minimize setting drift, pressure settings should fall within the middle 80 percent of the pressure range.
Table 22.49: Fixed Differential [5]
NEMA 4, 4X, 13 Enclosure
UL Listed and CSA Certified As Industrial Control Equipment
Range on
Decreasing
Pressure
psig
[6]Approximate
Differential at
Mid-Range
psig
Maximum
Allowable
Pressure
psig
Single Pole
Double Throw
Double Pole
Double Throw
Catalog No. Catalog No.
Diaphragm Actuated—Nitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing
.2–10 0.6 ±0.1 100 9012GDW1 9012GDW21
1–40 1.6 ±0.4 100 9012GDW2 9012GDW22
1.5–75 3.0 ±0.5 240 9012GDW4 9012GDW24
3–150 6.0 ±0.8 475 9012GDW5 9012GDW25
5–250 10.0 ±1.5 750 9012GDW6 9012GDW26
13–425 16 ±3.5 850 9012GEW1 9012GEW21
20–675 27 ±5 2000 9012GEW2 9012GEW22
Piston Actuated—#440 Stainless Steel Piston. #303 Stainless Steel Housing,
Viton
®
Fluorocarbon Diaphragm and O-ring, Teflon
®
Retaining Ring
20–1000 59 ±9 10000 9012GFW1 9012GFW21
90–2900 170 ±15 15000 9012GFW2 9012GFW22
170–5600 289 ±55 20000 9012GFW3 9012GFW23
270–9000 495 ±70 25000 9012GFW4 9012GFW24
Table 22.50: Adjustable Differential [5]
NEMA 4, 4X, 13 EnclosureUL Listed and CSA Certified As
Industrial Control Equipment
Range on
Decreasing
Pressure
psig
[6]Adjustable
Differential
Approximate
at Mid-Range
Maximum
Allowable
Pressure
psig
Single Pole
Double Throw
Double Pole
Double Throw
Catalog No. Catalog No.
Diaphragm Actuated—Nitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing
.2–10 0.6–2 100 9012GAW1 9012GAW21
1–40 1.6–8 100 9012GAW2 9012GAW22
1.5–75 3.5–15 240 9012GAW4 9012GAW24
3–150 6.0–30 475 9012GAW5 9012GAW25
5–250 10.0–49 750 9012GAW6 9012GAW26
13–425 16–90 850 9012GBW1 9012GBW21
20–675 27–130 2000 9012GBW2 9012GBW22
Piston Actuated—#440 Stainless Steel Piston. #303 Stainless Steel Housing,
Viton Fluorocarbon Diaphragm and O-ring, Teflon
®
Retaining Ring
20–1000 59–200 10000 9012GCW1 9012GCW21
90–2900 170–560 15000 9012GCW2 9012GCW22
170–5600 289–1260 20000 9012GCW3 9012GCW23
270–9000 495–1900 25000 9012GCW4 9012GCW24
Table 22.51: Fixed Differential
NEMA 7 & 9 Enclosure
Class I & II, Division 1 & 2, Groups C, D, E, F, G
Range on
Decreasing
Pressure
psig
[6]Approximate
Differential at
Mid-Range
psig
Maximum
Allowable
Pressure
psig
Single Pole
Double Throw
Double Pole
Double Throw
Catalog No. Catalog No.
Diaphragm Actuated—Nitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing
0.2–10 1.0 ±0.1 100 9012GDR1
1–40 2.4 ±0.8 100 9012GDR2 9012GDR22
1.5–75 4.5 ±1 240 9012GDR4 9012GDR24
3–150 9 ±1.5 475 9012GDR5 9012GDR25
5–250 15 ±3 750 9012GDR6 9012GDR26
13–425 25 ±7 850 9012GER1 9012GER21
Piston Actuated—#440 Stainless Steel Piston. #303 Stainless Steel Housing,
Viton Fluorocarbon Diaphragm and O-ring, Teflon
®
Retaining Ring
20–1000 89 ±18 10000 9012GFR1 9012GFR21
90–2900 255 ±30 15000 9012GFR2 9012GFR22
170–5600 578 ±110 20000 9012GFR3
Acceptable Wire Sizes: 12–22 AWG
Recommended Terminal Clamp Torque: 7 lb-in
Electrical Rating: see page 22-19
Temperature Rating: see page 22-19
Modifications: see page 22-21
Accessories: see page 22-21
Renewal Parts Kits: see page 22-34
Dimensions: see page 22-20
Table 22.52: Adjustable Differential
NEMA 7 & 9 Enclosure
Class I & II, Division 1 & 2, Groups C, D, E, F, G
Range on
Decreasing
Pressure
psig
[6]Adjustable
Differential
Approximate
at Mid-Range
Maximum
Allowable
Pressure
psig
Single Pole
Double Throw
Double Pole
Double Throw
Catalog No. Catalog No.
Diaphragm Actuated—Nitrile (Buna-N) Diaphragm, Zinc Plated Steel Housing
0.2–10 1.0–2 100 9012GAR1 9012GAR21
1–40 2.4–8 100 9012GAR2 9012GAR22
1.5–75 4.5–15 240 9012GAR4 9012GAR24
3–150 9–35 475 9012GAR5 9012GAR25
5–250 15–49 750 9012GAR6 9012GAR26
13–425 25–90 850 9012GBR1 9012GBR21
20–675 41–130 2000 9012GBR2 9012GBR22
Piston Actuated—#440 Stainless Steel Piston. #303 Stainless Steel Housing,
Viton Fluorocarbon Diaphragm and O-ring, Teflon
®
Retaining Ring
20–1000 89–200 10000 9012GCR1 9012GCR21
90–2900 255–560 15000 9012GCR2
170–5600 578–1260 20000 9012GCR3 9012GCR23
270–9000 788–1900 25000 9012GCR4
File: E12443
Haz. Loc.
CCN NOWT G•R
File:
LR25490
Class 3211-03
G•W, G•O, G•G
Complies with IEC 60957.5.1,
5C8.3.4 when protected with a
Bussmann CCKTK-R-10 fuse.
File: E12158 CCN NKPZ
G•O, G•G, G•W
File:
LR26817
Class 3218-02 G•R
File: E12158 CCN NTHT
Marine Use, G•W
22
PRESSURE, VACUUM, AND FLOAT
SWITCHES
[5] For metric threads, add M after the W on all types (offered at an additional cost).
To order a Pg13.5 electrical conduit entry and a 1/4”-19 BSP pressure connection, add M12 to the end of the catalog number, as well as adding “M” after “W” for metric threads. For example:
9012GAW1 = 1/2” NPT electrical conduit entry
9012GAWM1 = 20 x 1.5 mm electrical conduit entry
9012GAWM1M12 = Pg13.5 electrical conduit entry and 1/4-19 BSP pressure connection.
[6] The differential adds to the range setting and determines the operating point on rising pressure.