Brochure
Table Of Contents
- AC Magnetic Contactors Class 8502
- AC Magnetic Starters Class 8536
- Class 8502 and 8536 Application Data
- Power Contact Ratings
- Short Circuit Protection
- Capacitor Switching
- Maintenance of Equipment
- Auxiliary Units
- Factory Installed Auxiliary Contacts
- Form Number of Additional Auxiliary Contacts
- Control Circuit Transformers
- Power Poles
- Size 6 Type SH and Size 7 Type SJ Contactors and Starters
- Operation Rates
- Auxiliary Contacts
- Class 8502 Open Type Class 8536 Open Type
- NEMA Type 1 — General Purpose Enclosure
- NEMA Type 1 — General Purpose Enclosure with Form F4T
- NEMA Type 7 & 9 Enclosures for Hazardous Locations Sizes 0-2, Bolted Cover, Cast Iron, Sizes 0-5,...
- NEMA 7 & 9 Bolted Cover, Cast Aluminum
- General Information
- Altitude
- Termination Means
- Auxiliary Contacts
- Auxiliary Contact Units
- section 2 – reversing magnetic starters and contactors
- AC Magnetic Reversing Contactors Class 8702
- AC magnetic reversing starters class 8736
- General Information
- Overload Relays
- MOTOR LOGIC™ Solid State Overload Relay (SSOLR)
- Enclosures
- Holding Circuit Contact
- Coil Voltages
- Mechanical Interlocks
- Auxiliary Contacts
- Type S Accessories
- Power Contact Ratings
- Maintenance of Equipment
- Control Transformer Selection
- Auxiliary Units
- Factory Installed Auxiliary Contacts
- Open Type — 2 or 3-Pole Only
- Auxiliary Contact Units
- General Information
- section 3 – motor starters multi-speed
- Additional Features
- Special Relays for Non-Reversing and Reversing Multispeed Starters
- Thermal Units
- Typical Elementray Diagrams
- Thermal Units
- Vertically Arranged, Open Type, Two Speed Starters
- Thermal Units
- Special Arrangements with Three Devices
- Ordering Information Required
- Thermal Units
- Thermal Units
- Application Data for Types SB-SH
- Control Transformer Selection
- Mechanical Interlock
- Section 1 – magnetic contactors and starters
© 1998 Square D All Rights Reserved
6
5/98
600 Volts AC Maximum — 50-60 Hertz
NEMA
Size
Continuous
Current
Ratings
Motor Volts Max. HP
t
Coil Voltage
Open Type
NEMA Type 1
General
Purpose
Enclosure
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Size 0-5)
f
Type Type Type
1-Pole Single Phase
018
115 1 120 SBO5V02 SBG5V02 SBW15V02
230 2 240 SBO5V03 SBG5V03 SBW15V03
127
115 2 120 SCO5V02 SCG5V02 SCW15V02
230 3 240 SCO5V03 SCG5V03 SCW15V03
2-Pole Single Phase
00 9
115
1
⁄
3
120 SAO11V02 SAG11V02
Use Size 0
230 1 240 SAO11V03 SAG11V03
018
115 1 120 SBO1V02 SBG1V02 SBW11V02
230 2 240 SBO1V03 SBG1V03 SBW11V03
127
115 2 120 SCO1V02 SCG1V02 SCW11V02
230 3 240 SCO1V03 SCG1V03 SCW11V03
245
115 3 120 SDO1V02 SDG1V02 SDW11V02
230 7
1
⁄
2
240 SDO1V03 SDG1V03 SDW11V03
3 90 . . . . . .
120 SEO1V02 SEG1V02 SEW11V02
240 SEO1V03 SEG1V03 SEW11V03
4 135 . . . . . .
120 SFO1V02 SFG1V02 SFW11V02
240 SFO1V03 SFG1V03 SFW11V03
5 270 . . . . . .
120 SGO1V02 SGG1V02 SGW11V02
240 SGO1V03 SGG1V03 SGW11V03
6 540 . . . . . .
120 SHO1V02 SHG1V02 SHW1V02
240 SHO1V03 SHG1V03 SHW1V03
7 810 . . . . . .
120 SJO1V02 SJG1V02 SJW1V02
240 SJO1V03 SJG1V03 SJW1V03
4-Pole Polyphase
018
Separate Control
j
120 SBO3V02S SBG3V02S SBW13V02S
200 3 208 SBO3V08 SBG3V08 SBW13V08
230 3 240 SBO3V03 SBG3V03 SBW13V03
460 5 480 SBO3V06 SBG3V06 SBW13V06
575 5 600 SBO3V07 SBG3V07 SBW13V07
127
Separate Control
j
120 SCO3V02S SCG3V02S SCW13V02S
200 7
1
⁄
2
208 SCO3V08 SCG3V08 SCW13V08
230 7
1
⁄
2
240 SCO3V03 SCG3V03 SCW13V03
460 10 480 SCO3V06 SCG3V06 SCW13V06
575 10 600 SCO3V07 SCG3V07 SCW13V07
245
Separate Control
j
120 SDO3V02S SDG3V02S SDW13V02S
200 10 208 SDO3V08 SDG3V08 SDW13V08
230 15 240 SDO3V03 SDG3V03 SDW13V03
460 25 480 SDO3V06 SDG3V06 SDW13V06
575 25 600 SDO3V07 SDG3V07 SDW13V07
390
Separate Control
j
120 SEO3V02S SEG3V02S SEW13V02S
200 25 208 SEO3V08 SEG3V08 SEW13V08
230 30 240 SEO3V03 SEG3V03 SEW13V03
460 50 480 SEO3V06 SEG3V06 SEW13V06
575 50 600 SEO3V07 SEG3V07 SEW13V07
4 135
Separate Control
j
120 SFO3V02S SFG3V02S SFW13V02S
200 40 208 SFO3V08 SFG3V08 SFW13V08
230 50 240 SFO3V03 SFG3V03 SFW13V03
460 100 480 SFO3V06 SFG3V06 SFW13V06
575 100 600 SFO3V07 SFG3V07 SFW13V07
5-Pole Polyphase
018
Separate Control
j
120 SBO4V02S SBG4V02S SBW14V02S
200 3 208 SBO4V08 SBG4V08 SBW14V08
230 3 240 SBO4V03 SBG4V03 SBW14V03
460 5 480 SBO4V06 SBG4V06 SBW14V06
575 5 600 SBO4V07 SBG4V07 SBW14V07
127
Separate Control
j
120 SCO4V02S SCG4V02S SCW14V02S
200 7
1
⁄
2
208 SCO4V08 SCG4V08 SCW14V08
230 7
1
⁄
2
240 SCO4V03 SCG4V03 SCW14V03
460 10 480 SCO4V06 SCG4V06 SCW14V06
575 10 600 SCO4V07 SCG4V07 SCW14V07
245
Separate Control
j
120 SDO4V02S SDG4V02S SDW14V02S
200 10 208 SDO4V08 SDG4V08 SDW14V08
230 15 240 SDO4V03 SDG4V03 SDW14V03
460 25 480 SDO4V06 SDG4V06 SDW14V06
575 25 600 SDO4V07 SDG4V07 SDW14V07
390
Separate Control
j
120 SEO4V02S SEG4V02S SEW14V02S
200 25 208 SEO4V08 SEG4V08 SEW14V08
230 30 240 SEO4V03 SEG4V03 SEW14V03
460 50 480 SEO4V06 SEG4V06 SEW14V06
575 50 600 SEO4V07 SEG4V07 SEW14V07
4 135
Separate Control
j
120 SFO4V02S SFG4V02S SFW14V02S
200 40 208 SFO4V08 SFG4V08 SFW14V08
230 50 240 SFO4V03 SFG4V03 SFW14V03
460 100 480 SFO4V06 SFG4V06 SFW14V06
575 100 600 SFO4V07 SFG4V07 SFW14V07
f
Size 6 and 7 are painted sheet steel rated NEMA Type 4 only.
j
120 Volt Polyphase contactors are wired for separate control.
t
Coil voltage code must be specified to order this product. Refer to standard voltage codes listed in selection table above or additional standard
voltage codes and insert as shown in the HOW TO ORDER block on Page 5.
Full Voltage Contactors — NEMA
Selection – Class 8502