Brochure

Table Of Contents
© 1998 Square D All Rights Reserved
4
5/98
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz
NEMA
Size
Continuous
Current
Ratings
Motor Volts Max. HP
t
Coil Voltage
Open Type
NEMA Type 1
General
Purpose
Enclosure
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Size 0-5)
f
Type Type Type
00 9
Separate Control
j
120 SAO12V02S SAG12V02S
USE Size 0
200 1
1
2
208 SAO12V08 SAG12V08
230 1
1
2
240 SAO12V03 SAG12V03
460 2 480 SAO12V06 SAG12V06
575 2 600 SAO12V07 SAG12V07
018
Separate Control
j
120 SBO2V02S SBG2V02S SBW12V02S
200 3 208 SBO2V08 SBG2V08 SBW12V08
230 3 240 SBO2V03 SBG2V03 SBW12V03
460 5 480 SBO2V06 SBG2V06 SBW12V06
575 5 600 SBO2V07 SBG2V07 SBW12V07
127
Separate Control
j
120 SCO2V02S SCG2V02S SCW12V02S
200 7
1
2
208 SCO2V08 SCG2V08 SCW12V08
230 7
1
2
240 SCO2V03 SCG2V03 SCW12V03
460 10 480 SCO2V06 SCG2V06 SCW12V06
575 10 600 SCO2V07 SCG2V07 SCW12V07
245
Separate Control
j
120 SDO2V02S SDG2V02S SDW12V02S
200 10 208 SDO2V08 SDG2V08 SDW12V08
230 15 240 SDO2V03 SDG2V03 SDW12V03
460 25 480 SDO2V06 SDG2V06 SDW12V06
575 25 600 SDO2V07 SDG2V07 SDW12V07
390
Separate Control
j
120 SEO2V02S SEG2V02S SEW12V02S
200 25 208 SEO2V08 SEG2V08 SEW12V08
230 30 240 SEO2V03 SEG2V03 SEW12V03
460 50 480 SEO2V06 SEG2V06 SEW12V06
575 50 600 SEO2V07 SEG2V07 SEW12V07
4 135
Separate Control
j
120 SFO2V02S SFG2V02S SFW12V02S
200 40 208 SFO2V08 SFG2V08 SFW12V08
230 50 240 SFO2V03 SFG2V03 SFW12V03
460 100 480 SFO2V06 SFG2V06 SFW12V06
575 100 600 SFO2V07 SFG2V07 SFW12V07
5 270
Separate Control
j
120 SGO2V02S SGG2V02S SGW12V02S
200 75 208 SGO2V08 SGG2V08 SGW12V08
230 100 240 SGO2V03 SGG2V03 SGW12V03
460 200 480 SGO2V06 SGG2V06 SGW12V06
575 200 600 SGO2V07 SGG2V07 SGW12V07
6 540
Separate Control
j
120 SHO2V02S SHG2V02S SHW12V02S
200 150 208 SHO2V08 SHG2V08 SHW12V08
230 200 240 SHO2V03 SHG2V03 SHW12V03
460 400 480 SHO2V06 SHG2V06 SHW12V06
575 400 600 SHO2V07 SHG2V07 SHW12V07
7 810
Separate Control
j
120 SJO2V02S SJG2V02S SJW12V02S
200 . . . 208 SJO2V08 SJG2V08 SJW12V08
230 300 240 SJO2V03 SJG2V03 SJW12V03
460 600 480 SJO2V06 SJG2V06 SJW12V06
575 600 600 SJO2V07 SJG2V07 SJW12V07
f
Size 6 and 7 are painted sheet steel rated NEMA Type 4 only.
j
120 Volt Polyphase contactors are wired for separate control.
t
Coil voltage code must be specified to order this product. Refer to standard voltage codes listed below and insert as shown in How to Order.
Coil Voltage Codes
Voltage
Code
60 Hz 50 Hz
24
q
. . . VO1
120 110 VO2
208 . . . VO8
240 220 VO3
480 440 VO6
600 550 VO7
Specify Specify V99
q
24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
Full Voltage Contactors — NEMA
Selection – Class 8502
Factory Modifications (FORMS)
...............Refer to Catalog 9999CT9701
Application Data
................................................................... Pages 13-16
Dimensions
........................................................................... Pages 17-20
Separate Enclosures (Class 9991)
...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998)
..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999)
.............Refer to Catalog 9999CT9701
How to Order:
To Order Specify: Catalog Number
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Class Type Coil
Voltage
Code
Form(s)
8502 SBG2 VO2 P1S
Type SC02
Size 1, 3-Pole Contactor
File LR12751
Class 3211-04
File E78351
CCN NLDX
File 60905
Class 3211-04
IEC 947-4-1
Sizes 00-5 only