Brochure

Table Of Contents
© 1998 Square D All Rights Reserved
30
5/98
600 Volts AC Maximum — 50-60 Hertz
NEMA
Size
Continuous
Current
Ratings
Motor
Volts
Max.
HP
Type of
Motor
t
Coil
Voltage
Open Type
NEMA
Type 1
General
Purpose
Enclosure
NEMA Type 4 & 4X
Watertight,
Dusttight
Brushed Stainless
Steel Enclosure
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Groups E, F & G
NEMA Type 12
Dusttight &
Driptight
Industrial Use
Enclosure
Vertical
Type
Horizontal
Type
Type Type Bolted Type
SPIN TOP
®
Type
Type
2-Pole Single Phase
00 9
115
1
3
Single
Phase
3-Wire
120 . . . SAO1V02 SAG1V02
Use Size 0 Use Size 0 Use Size 0 Use Size 0
230 1 240 . . . SAO1V03 SAG1V03
018
115 1 120 SBO9V02 SBO1V02 SBG1V02 SBW11V02 SBT46V02 SBR6V02 SBA1V02
230 2 240 SBO9V03 SBO1V03 SBG1V03 SBW11V03 SBT46V03 SBR6V03 SBA1V03
127
115 2 120 SCO1V02 SCO2V02 SCG2V02 SCW11V02 SCT46V02 SCR6V02 SCA1V02
230 3 240 SCO1V03 SCO2V03 SCG2V03 SCW11V03 SCT46V03 SCR6V03 SCA1V03
3-Pole Single Phase
00 9
115
1
3
4-Wire
Rep.-Ind.
120 . . . SAO2V02 SAG2V02
Use Size 0 Use Size 0 Use Size 0 Use Size 0
230 1 240 . . . SAO2V03 SAG2V03
115
1
3
4-Wire
Split Ph.
120 . . . SAO3V02 SAG3V02
Use Size 0 Use Size 0 Use Size 0 Use Size 0
230 1 240 . . . SAO3V03 SAG3V03
018
115 1 4-Wire
Rep.-Ind.
120 SBO10V02 SBO2V02 SBG2V02 SBW12V02 SBT47V02 SBR7V02 SBA2V02
230 2 240 SBO10V03 SBO2V03 SBG2V03 SBW12V03 SBT47V03 SBR7V03 SBA2V03
115 1 4-Wire
Split Ph.
120 SBO11V02 SBO3V02 SBG3V02 SBW13V02 SBT48V02 SBR8V02 SBA3V02
230 2 240 SBO11V03 SBO3V03 SBG3V03 SBW13V03 SBT48V03 SBR8V03 SBA3V03
127
115 2 4-Wire
Rep.-Ind.
120 SCO3V02 SCO4V02 SCG4V02 SCW12V02 SCT47V02 SCR7V02 SCA2V02
230 3 240 SCO3V03 SCO4V03 SCG4V03 SCW12V03 SCT47V03 SCR7V03 SCA2V03
115 2 4-Wire
Split Ph.
120 SCO5V02 SCO6V02 SCG6V02 SCW13V02 SCT48V02 SCR8V02 SCA3V02
230 3 240 SCO5V03 SCO6V03 SCG6V03 SCW13V03 SCT48V03 SCR8V03 SCA3V03
4-Pole Polyphase
018
Separate Control
2 Phase
2 Wire
120 SBO13V02S SBO5V02S SBG5V02S SBW15V02S
Consult Local
Square D
Field Office
SBR10V02S SBA5V02S
200 3 208 SBO13V08 SBO5V08 SBG5V08 SBW15V08 SBR10V08 SBA5V08
230 3 240 SBO13V03 SBO5V03 SBG5V03 SBW15V03 SBR10V03 SBA5V03
460 5 480 SBO13V06 SBO5V06 SBG5V06 SBW15V06 SBR10V06 SBA5V06
575 5 600 SBO13V07 SBO5V07 SBG5V07 SBW15V07 SBR10V07 SBA5V07
127
Separate Control 120 SCO9V02S SCO10V02S SCG10V02S SCW15V02S
Consult Local
Square D
Field Office
SCR10V02S SCA5V02S
200 7
1
2
208 SCO9V08 SCO10V08 SCG10V08 SCW15V08 SCR10V08 SCA5V08
230 7
1
2
240 SCO9V03 SCO10V03 SCG10V03 SCW15V03 SCR10V03 SCA5V03
460 10 480 SCO9V06 SCO10V06 SCG10V06 SCW15V06 SCR10V06 SCA5V06
575 10 600 SCO9V07 SCO10V07 SCG10V07 SCW15V07 SCR10V07 SCA5V07
245
Separate Control 120
. . .
SDO4V02S SDG4V02S SDW12V02S
Consult Local
Square D
Field Office
SDR4V02S SDA2V02S
200 10 208 SDO4V08 SDG4V08 SDW12V08 SDR4V08 SDA2V08
230 15 240 SDO4V03 SDG4V03 SDW12V03 SDR4V03 SDA2V03
460 25 480 SDO4V06 SDG4V06 SDW12V06 SDR4V06 SDA2V06
575 25 600 SDO4V07 SDG4V07 SDW12V07 SDR4V07 SDA2V07
390
Separate Control 120
. . .
SEO4V02S SEG4V02S SEW12V02S
. . . . . .
SEA2V02S
200 25 208 SEO4V08 SEG4V08 SEW12V08 SEA2V08
230 30 240 SEO4V03 SEG4V03 SEW12V03 SEA2V03
460 50 480 SEO4V06 SEG4V06 SEW12V06 SEA2V06
575 50 600 SEO4V07 SEG4V07 SEW12V07 SEA2V07
4 135
Separate Control 120
. . .
SFO4V02S SFG4V02S SFW12V02S
. . . . . .
SFA2V02S
200 40 208 SFO4V08 SFG4V08 SFW12V08 SFA2V08
230 50 240 SFO4V03 SFG4V03 SFW12V03 SFA2V03
460 100 480 SFO4V06 SFG4V06 SFW12V06 SFA2V06
575 100 600 SFO4V07 SFG4V07 SFW12V07 SFA2V07
t Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
Coil Voltage Codes
Voltage
Code
60 Hz 50 Hz
24q . . . V01j
120 110 V02j
208 . . . V08
240 220 V03
480 440 V06
600 550 V07
Specify Specify V99
q 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
j These voltage codes must include Form S (supplied at N.C.).
Full Voltage Reversing Contactors — NEMA
Selection – Class 8702
Factory Modifications (FORMS)...............Refer to Catalog 9999CT9701
Application Data .................................................................... Page 33, 37
Dimensions ........................................................................... Pages 34-36
Separate Enclosures (Class 9991)...........Refer to Catalog 9999CT9701
Replacement Parts (Class 9998) ..............Refer to Catalog 9999CT9701
Type S Accessories (Class 9999).............Refer to Catalog 9999CT9701
How to Order:
To Order Specify: Catalog Number
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Class Type Coil
Voltage
Code
Form(s)
8702 SCG2 VO2 P1S
File LR60905
Class 3211-04
File E78351
CCN NLDX