Brochure

Table Of Contents
29
5/98
© 1998 Square D All Rights Reserved
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz
NEMA
Size
Continuous
Current Ratings
Motor
Volts
Max.
HP
t
Coil
Voltage
Open Type
NEMA Type 1
General
Purpose
Enclosure
NEMA Type 4 & 4X
Watertight, Dusttight
Brushed Stainless
Steel Enclosure
(Sizes 0-5)f
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Groups E, F & G
NEMA Type 12
Dusttight &
Driptight
Industrial Use
Enclosure
Vertical
Type
Horizontal
Type
Type Type
Bolted Type
Aluminum
SPIN TOP
®
Type
Type
00 9
Separate Controlj 120 . . . SAO4V02S SAG4V02S
Use Size 0 Use Size 0 Use Size 0 Use Size 0
200 1
1
2
208 . . . SAO4V08 SAG4V08
230 1
1
2
240 . . . SAO4V03 SAG4V03
460 2 480 . . . SAO4V06 SAG4V06
575 2 600 . . . SAO4V07 SAG4V07
018
Separate Controlj 120 SBO12V02S SBO4V02S SBG4V02S SBW14V02S SBT49V02S SBR9V02S SBA4V02S
200 3 208 SBO12V08 SBO4V08 SBG4V08 SBW14V08 SBT49V08 SBR9V08 SBA4V08
230 3 240 SBO12V03 SBO4V03 SBG4V03 SBW14V03 SBT49V03 SBR9V03 SBA4V03
460 5 480 SBO12V06 SBO4V06 SBG4V06 SBW14V06 SBT49V06 SBR9V06 SBA4V06
575 5 600 SBO12V07 SBO4V07 SBG4V07 SBW14V07 SBT49V07 SBR9V07 SBA4V07
127
Separate Controlj 120 SCO7V02S SCO8V02S SCG8V02S SCW14V02S SCT49V02S SCR9V02S SCA4V02S
200 7
1
2
208 SCO7V08 SCO8V08 SCG8V08 SCW14V08 SCT49V08 SCR9V08 SCA4V08
230 7
1
2
240 SCO7V03 SCO8V03 SCG8V03 SCW14V03 SCT49V03 SCR9V03 SCA4V03
460 10 480 SCO7V06 SCO8V06 SCG8V06 SCW14V06 SCT49V06 SCR9V06 SCA4V06
575 10 600 SCO7V07 SCO8V07 SCG8V07 SCW14V07 SCT49V07 SCR9V07 SCA4V07
245
Separate Controlj 120 SDO1V02S SDO2V02S SDG2V02S SDW11V02S SDT43V02S SDR3V02S SDA1V02S
200 10 208 SDO1V08 SDO2V08 SDG2V08 SDW11V08 SDT43V08 SDR3V08 SDA1V08
230 15 240 SDO1V03 SDO2V03 SDG2V03 SDW11V03 SDT43V03 SDR3V03 SDA1V03
460 25 480 SDO1V06 SDO2V06 SDG2V06 SDW11V06 SDT43V06 SDR3V06 SDA1V06
575 25 600 SDO1V07 SDO2V07 SDG2V07 SDW11V07 SDT43V07 SDR3V07 SDA1V07
390
Separate Controlj 120 SEO1V02S SEO2V02S SEG2V02S SEW11V02S SET43V02S SER3V02S SEA1V02S
200 25 208 SEO1V08 SEO2V08 SEG2V08 SEW11V08 SET43V08 SER3V08 SEA1V08
230 30 240 SEO1V03 SEO2V03 SEG2V03 SEW11V03 SET43V03 SER3V03 SEA1V03
460 50 480 SEO1V06 SEO2V06 SEG2V06 SEW11V06 SET43V06 SER3V06 SEA1V06
575 540 600 SEO1V07 SEO2V07 SEG2V07 SEW11V07 SET43V07 SER3V07 SEA1V07
4 135
Separate Controlj 120 SFO1V02S SFO3V02S SFG3V02S SFW11V02S
. . . . . .
SFA1V02S
200 40 208 SFO1V08 SFO3V08 SFG3V08 SFW11V08 SFA1V08
230 50 240 SFO1V03 SFO3V03 SFG3V03 SFW11V03 SFA1V03
460 100 480 SFO1V06 SFO3V06 SFG3V06 SFW11V06 SFA1V06
575 100 600 SFO1V07 SFO3V07 SFG3V07 SFW11V07 SFA1V07
5 270
Separate Controlj 120 SGO1V02S SGO3V02S SGG3V02S SGW11V02S
. . . . . .
SGA1V02S
200 75 208 SGO1V08 SGO3V08 SGG3V08 SGW11V08 SGA1V08
230 100 240 SGO1V03 SGO3V03 SGG3V03 SGW11V03 SGA1V03
460 200 480 SGO1V06 SGO3V06 SGG3V06 SGW11V06 SGA1V06
575 200 600 SGO1V07 SGO3V07 SGG3V07 SGW11V07 SGA1V07
6 540
Separate Controlj 120
. . .
SHO1V02S SHG1V02S SHW1V02S
. . . . . .
SHA1V02S
200 150 208 SHO1V08 SHG1V08 SHW1V08 SHA1V08
230 200 240 SHO1V03 SHG1V03 SHW1V03 SHA1V03
460 400 480 SHO1V06 SHG1V06 SHW1V06 SHA1V06
575 400 600 SHO1V07 SHG1V07 SHW1V07 SHA1V07
7 810
Separate Controlj 120
. . .
SJO1V02S SJG1V02S SJW1V02S
. . . . . .
SJA1V02S
200 208 SJO1V08 SJG1V08 SJW1V08 SJA1V08
230 300 240 SJO1V03 SJG1V03 SJW1V03 SJA1V03
460 600 480 SJO1V06 SJG1V06 SJW1V06 SJA1V06
575 600 600 SJO1V07 SJG1V07 SJW1V07 SJA1V07
f Size 6 and 7 are rated NEMA Type 4 only.
j 120 Volt Polyphase contactors are wired for separate control.
t Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes below and insert as shown
in the HOW TO ORDER block.
Coil Voltage Codes
Voltage
Code
60 Hz 50 Hz
24q . . . V01jq
120 110 V02j
208 . . . V08
240 220 V03
480 440 V06
600 550 V07
Specify Specify V99
q 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
j These voltage codes must include Form S (supplied at N.C.).
Full Voltage Reversing Contactors — NEMA
Selection – Class 8702
Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701
Application Data.....................................................................Page 33, 37
Dimensions............................................................................Pages 34-36
Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998).............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999).............Refer to Catalog 9999CT9701
How to Order:
To Order Specify: Catalog Number
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Class Type Coil
Voltage
Code
Form(s)
8702 SCG8 VO2 P1S