Brochure
Table Of Contents
- AC Magnetic Contactors Class 8502
- AC Magnetic Starters Class 8536
- Class 8502 and 8536 Application Data
- Power Contact Ratings
- Short Circuit Protection
- Capacitor Switching
- Maintenance of Equipment
- Auxiliary Units
- Factory Installed Auxiliary Contacts
- Form Number of Additional Auxiliary Contacts
- Control Circuit Transformers
- Power Poles
- Size 6 Type SH and Size 7 Type SJ Contactors and Starters
- Operation Rates
- Auxiliary Contacts
- Class 8502 Open Type Class 8536 Open Type
- NEMA Type 1 — General Purpose Enclosure
- NEMA Type 1 — General Purpose Enclosure with Form F4T
- NEMA Type 7 & 9 Enclosures for Hazardous Locations Sizes 0-2, Bolted Cover, Cast Iron, Sizes 0-5,...
- NEMA 7 & 9 Bolted Cover, Cast Aluminum
- General Information
- Altitude
- Termination Means
- Auxiliary Contacts
- Auxiliary Contact Units
- section 2 – reversing magnetic starters and contactors
- AC Magnetic Reversing Contactors Class 8702
- AC magnetic reversing starters class 8736
- General Information
- Overload Relays
- MOTOR LOGIC™ Solid State Overload Relay (SSOLR)
- Enclosures
- Holding Circuit Contact
- Coil Voltages
- Mechanical Interlocks
- Auxiliary Contacts
- Type S Accessories
- Power Contact Ratings
- Maintenance of Equipment
- Control Transformer Selection
- Auxiliary Units
- Factory Installed Auxiliary Contacts
- Open Type — 2 or 3-Pole Only
- Auxiliary Contact Units
- General Information
- section 3 – motor starters multi-speed
- Additional Features
- Special Relays for Non-Reversing and Reversing Multispeed Starters
- Thermal Units
- Typical Elementray Diagrams
- Thermal Units
- Vertically Arranged, Open Type, Two Speed Starters
- Thermal Units
- Special Arrangements with Three Devices
- Ordering Information Required
- Thermal Units
- Thermal Units
- Application Data for Types SB-SH
- Control Transformer Selection
- Mechanical Interlock
- Section 1 – magnetic contactors and starters
© 1998 Square D All Rights Reserved
22
5/98
NEMA Type 12 — Dusttight Enclosure
NEMA
Size
Class Type
No.
of
Poles
Dimensions – Inches/mm (Figure 16) Weight (Lbs)
ABCDEFGHI J
Class
8502
Class
8536
0
8502 & 8536
SBA
All
6.38
162
8.53
217
12.75
324
1.56
40
3.25
83
12.00
305
.38
10
3.56
90
12.25
311
.31
8
15 16
1 SCA
2 8502 & 8536 SDA All
8.13
207
9.28
236
16.00
406
1.56
40
5.00
127
15.00
381
.50
13
3.56
90
15.38
391
.31
8
22 23
3
8502 & 8536
SEA
All
18.16
461
9.56
243
31.50
800
3.08
78
12.00
305
30.50
775
.50
13
4.50
114
26.72
679
.44
11
65 68
4SFA 69 73
5 8502 & 8536 SGA All
17.22
437
13.44
341
47.00
1194
4.13
105
9.00
229
46.00
1168
.50
13
5.41
137
28.31
719
.56
14
160 177
6 8502 & 8536 SHA All
20.22
514
13.00
330
65.00
1651
4.13
105
12.00
305
64.00
1626
.50
13
6.44
164
30.88
784
.69
18
228 233
7 8502 & 8536 SJA All
34.50
876
23.50
597
93.00
2362
Floor Mounting . . . . . .
NEMA Type 12 — Dusttight Enclosure with Form F4T
NEMA
Size
Class Type
No.
of
Poles
Dimensions – Inches/mm (Figure 17)
ABCDEFGHI J
IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm IN mm
0
8502 & 8536
SBA
All 11.88 302 8.00 203 13.50 343 2.81 71 6.75 171 12.75 324 .38 10 3.91 99 18.38 467 .31 8
1 SCA
2 8502 & 8536 SDA All 14.88 378 8.13 207 16.00 406 2.56 65 9.75 248 15.00 381 .38 10 3.66 93 21.50 546 .31 8
3
8502 & 8536
SEA
2–3
Same as Standard NEMA Type 12 dimensions, see above.4SFA
5 8502 & 8536 SGA All
6 8502 & 8536 SHA All
Form F4T is supplied as standard. Refer to Page 16.
7 8502 & 8536 SJA All
NEMA Type 3R — Rainproof and Sleet Resistant Enclosures
NEMA
Size
Class Type
No.
of
Poles
Dimensions — Inches/mm (Figure 17)
A B C D1 D2 E F G1 G2 H1 H2 J K L M N P
K.O.
X
K.O.
Y
0 & 1
8502 &
8536
SBH,
SCH
All
8.84
225
12.28
312
7.13
181
1.38
35
1.44
37
6.00
152
7.50
191
2.59
66
2.19
56
2.06
52
2.63
67
14.28
363
1.38
35
1.38
35
1.88
48
4.38
111
1.84
47
1
⁄
2
3
⁄
4
1
1
⁄
2
3
⁄
4
1
2
8502 &
8536
SDH All
9.84
250
16.28
414
8.63
219
1.38
35
1.44
37
7.00
178
11.50
292
2.59
66
2.19
56
2.06
52
2.63
67
16.78
426
1.31
33
1.75
44
2.13
54
4.88
124
1.84
47
1
1
1
⁄
4
1
1
⁄
2
1
⁄
2
3
⁄
4
3
8502 &
8536
SEH All
12.84
326
25.28
642
8.63
219
1.38
35
1.44
37
10.00
254
20.50
521
2.59
66
2.19
56
2.06
52
2.63
67
19.78
502
1.31
33
1.94
49
2.44
62
6.38
162
1.84
47
1
1
1
⁄
4
2
2
1
⁄
2
1
⁄
2
3
⁄
4
4
8502 &
8536
SFH All
12.84
326
40.28
1023
9.13
232
1.38
35
1.44
37
10.00
254
35.50
902
2.59
66
2.19
56
2.06
52
2.63
67
20.28
515
1.31
33
2.31
59
2.69
68
6.38
162
1.84
47
1
1
1
⁄
4
2
2
1
⁄
2
1
⁄
2
3
⁄
4
Full Voltage Contactors and Starters — NEMA
Approximate Dimensions, Shipping Weights – Class 8502, 8536
Figure 16
NEMA Type 12
Industrial Use
Enclosure
Figure 17
NEMA Type 12
Industrial Use
Enclosure
Figure 18
NEMA Type 3R
Outdoor Use
Enclosure
F
G
G
DDE
C
B
A
I
H
(4) J Dia.
Mounting Holes
F
G
G
DDE
C
B
A
I
H
(4) J Dia.
Mounting Holes
F
G
G
DDE
C
B
A
I
H
(4) J Dia.
Mounting Holes