Brochure
Table Of Contents
- AC Magnetic Contactors Class 8502
- AC Magnetic Starters Class 8536
- Class 8502 and 8536 Application Data
- Power Contact Ratings
- Short Circuit Protection
- Capacitor Switching
- Maintenance of Equipment
- Auxiliary Units
- Factory Installed Auxiliary Contacts
- Form Number of Additional Auxiliary Contacts
- Control Circuit Transformers
- Power Poles
- Size 6 Type SH and Size 7 Type SJ Contactors and Starters
- Operation Rates
- Auxiliary Contacts
- Class 8502 Open Type Class 8536 Open Type
- NEMA Type 1 — General Purpose Enclosure
- NEMA Type 1 — General Purpose Enclosure with Form F4T
- NEMA Type 7 & 9 Enclosures for Hazardous Locations Sizes 0-2, Bolted Cover, Cast Iron, Sizes 0-5,...
- NEMA 7 & 9 Bolted Cover, Cast Aluminum
- General Information
- Altitude
- Termination Means
- Auxiliary Contacts
- Auxiliary Contact Units
- section 2 – reversing magnetic starters and contactors
- AC Magnetic Reversing Contactors Class 8702
- AC magnetic reversing starters class 8736
- General Information
- Overload Relays
- MOTOR LOGIC™ Solid State Overload Relay (SSOLR)
- Enclosures
- Holding Circuit Contact
- Coil Voltages
- Mechanical Interlocks
- Auxiliary Contacts
- Type S Accessories
- Power Contact Ratings
- Maintenance of Equipment
- Control Transformer Selection
- Auxiliary Units
- Factory Installed Auxiliary Contacts
- Open Type — 2 or 3-Pole Only
- Auxiliary Contact Units
- General Information
- section 3 – motor starters multi-speed
- Additional Features
- Special Relays for Non-Reversing and Reversing Multispeed Starters
- Thermal Units
- Typical Elementray Diagrams
- Thermal Units
- Vertically Arranged, Open Type, Two Speed Starters
- Thermal Units
- Special Arrangements with Three Devices
- Ordering Information Required
- Thermal Units
- Thermal Units
- Application Data for Types SB-SH
- Control Transformer Selection
- Mechanical Interlock
- Section 1 – magnetic contactors and starters
9
5/98
© 1998 Square D All Rights Reserved
3-Pole Polyphase — 600 Volts AC Maximum — 50-60 Hertz—Three Thermal Units Required
NEMA
Size
Continuous
Current
Ratings
Motor
Volts
Max.
HP
t
Coil
Voltage
NEMA Type 7 & 9
Hazardous Locations
Class I, Groups C & D
Class II, Class E, F, & G
NEMA Type 9
Hazardous Locations
Class II, Groups E, F, & G
NEMA Type 12/3R
k
Dusttight & Driptight
Industrial Use
Enclosure
Bolted Type
SPIN TOP
®
Type
Type Type
Cast Iron
c
Cast
Aluminum
00 9
Separate Control
j
120
USE Size 0 USE Size 0 USE Size 0 Use Size 0
200 1
1
⁄
2
208
230 1
1
⁄
2
240
460 2 480
575 2 600
018
Separate Control
j 120 SBT2V02S SBT42V02S SBR2V02S SBE2V02S SBA2V02S
200 3 208 SBT2V08 SBT42V08 SBR2V08 SBE2V08 SBA2V08
230 3 240 SBT2V03 SBT42V03 SBR2V03 SBE2V03 SBA2V03
460 5 480 SBT2V06 SBT42V06 SBR2V06 SBE2V06 SBA2V06
575 5 600 SBT2V07 SBT42V07 SBR2V07 SBE2V07 SBA2V07
127
Separate Controlj 120 SCT3V02S SCT43V02S SCR3V02S SCE3V02S SCA3V02S
200 7
1
⁄
2
208 SCT3V08 SCT43V08 SCR3V08 SCE3V08 SCA3V08
230 7
1
⁄
2
240 SCT3V03 SCT43V03 SCR3V03 SCE3V03 SCA3V03
460 10 480 SCT3V06 SCT43V06 SCR3V06 SCE3V06 SCA3V06
575 10 600 SCT3V07 SCT43V07 SCR3V07 SCE3V07 SCA3V07
245
Separate Controlj 120 SDT1V02S SDT41V02S SDR1V02S SDE1V02S SDA1V02S
200 10 208 SDT1V08 SDT41V08 SDR1V08 SDE1V08 SDA1V08
230 15 240 SDT1V03 SDT41V03 SDR1V03 SDE1V03 SDA1V03
460 25 480 SDT1V06 SDT41V06 SDR1V06 SDE1V06 SDA1V06
575 25 600 SDT1V07 SDT41V07 SDR1V07 SDE1V07 SDA1V07
390
Separate Controlj 120
. . .
SET43V02S SER3V02S SEE1V02S SEA1V02S
200 25 208 SET43V08 SER3V08 SEE1V08 SEA1V08
230 30 240 SET43V03 SER3V03 SEE1V03 SEA1V03
460 50 480 SET43V06 SER3V06 SEE1V06 SEA1V06
575 50 600 SET43V07 SER3V07 SEE1V07 SEA1V07
4 135
Separate Controlj 120
. . .
SFT41V02S SFR1V02S SFE1V02S SFA1V02S
200 40 208 SFT41V08 SFR1V08 SFE1V08 SFA1V08
230 50 240 SFT41V03 SFR1V03 SFE1V03 SFA1V03
460 100 480 SFT41V06 SFR1V06 SFE1V06 SFA1V06
575 100 600 SFT41V07 SFR1V07 SFE1V07 SFA1V07
5 270
Separate Controlj 120
. . .
SGT41V02S SGR1V02S SGE1V02S SGA1V02S
200 75 208 SGT41V08 SGR1V08 SGE1V08 SGA1V08
230 100 240 SGT41V03 SGR1V03 SGE1V03 SGA1V03
460 200 480 SGT41V06 SGR1V06 SGE1V06 SGA1V06
575 200 600 SGT41V07 SGR1V07 SGE1V07 SGA1V07
6 540
Separate Controlj 120
. . . . . . . . . . . .
SHA2V02S
200 150 208 SHA2V08
230 200 240 SHA2V03
460 400 480 SHA2V06
575 400 600 SHA2V07
7 810
Separate Controlj 120
. . . . . . . . . . . .
SJA2V02S
200 — 208 SJA2V08
230 300 240 SJA2V03
460 600 480 SJA2V06
575 600 600 SJA2V07
k For NEMA Type 3R enclosed devices (Sizes 0-4 only), change “A” in Type designation to “H”, no additional charge. Consult Factory for restrictions on available Forms in NEMA Type 3R
enclosures.
j 120 Volt Polyphase starters are wired for separate control.
c Limited to one Pilot Light and a Selector Switch or Start-Stop Push Button.
t Coil voltage code must be specified to order this product. Refer to standard coil voltage codes listed in selection table above or additional standard voltage codes in table below and insert
as shown in the HOW TO ORDER block.
Coil Voltage Codes
Voltage
Code
60 Hz 50 Hz
24q . . . VO1
120 110 VO2
208 . . . VO8
240 220 VO3
480 440 VO6
600 550 VO7
Specify Specify V99
q 24 V coils are not available on Sizes 4-7. On Sizes 00-3, where 24 V
coils are available, Form S (separate control) must be specified.
Full Voltage Starters — NEMA
Selection – Class 8536
Factory Modifications (FORMS)............... Refer to Catalog 9999CT9701
Application Data....................................................................Pages 13-16
Dimensions............................................................................Pages 17-20
Separate Enclosures (Class 9991)........... Refer to Catalog 9999CT9701
Replacement Parts (Class 9998).............. Refer to Catalog 9999CT9701
Type S Accessories (Class 9999) ............ Refer to Catalog 9999CT9701
How to Order:
To Order Specify: Catalog Number
• Class Number
• Type Number
• Coil Voltage Code
• Form(s)
Class Type Coil
Voltage
Code
Form(s)
8536 SBA2 VO2 H3O