Brochure

23-20
© 2017 Schneider Electric
All Rights Reserved
Industrial Relays
CAD
schneider-electric.us
Refer to Catalog 8501CT0101
TeSys™ D IEC Style Instantaneous Control Relays
CAD32
These 600 V relays are approved for use around the world. TeSys D relays are usually
mounted on 35 mm DIN track, but can also be mounted directly to a panel. The contacts
have NEMA A600 and Q600 ratings, in addition to the standard IEC ratings, making
them suitable for use in most any control circuit. Low consumption versions are available
for use with low level DC control signals from a computer or a PLC. Adder decks can be
added to a basic five pole relay to make it up to an 11 pole relay. The serrated silver-
nickel contacts with wiping action provide excellent reliability in 12 or 24 V control
circuits. Special auxiliary contacts are available for switching low power down to 5 V at
10 mA. Timer and mechanical latch attachments are available.
Table 23.57: Instantaneous Control Relays
Terminal Type
Number of Contacts
Contact Composition
Catalog
Number[1]
Normally Open Normally Closed
Screw Clamp
5
5 0 CAD50
3 2 CAD32
Spring Terminal
5
5 0 CAD503
3 2 CAD323
Ring Tongue
5
5 0 CAD506
3 2 CAD326
Table 23.58: Coil Voltage Codes:
12–240 Vac, 12–72 Vdc, 5–72 Vdc Low
Consumption
[2]
AC 50/60 Hz Coil (for additional voltage code options see page 7
of Catalog 8501CT0101).
Volts 12 24 48 120 208 240
Code J7 B7 E7 G7 LE7 U7
DC Coil (coils have built in suppression as standard)
Volts 12 24 36 48 60 72
Code JD BD CD ED ND SD
DC Low Consumption Coil (coils have built in suppression as
standard)
Volts 5 12 24 48 72
Code AL JL BL EL SL
Table 23.59: Coil Voltage Codes (cont.):
277–600 Vac, 110–440 Vdc
[2]
AC 50/60 Hz Coil (for additional voltage code options see page 7
of Catalog 8501CT0101).
Volts 277 480 600
Code W7 T7 X7
DC Coil (coils have built in suppression as standard)
Volts 110 125 220 250 440
Code FD GD MD UD RD
Table 23.60: Instantaneous Auxiliary Contact Blocks (for use in normal operation
environments)
Number of
Contacts
Maximum Number per
Device
Clip-on Mounting
Termination
Type
Contact Composition
Catalog
Number
Front
Left Side
Only
Normally Open
Normally Closed
2
1
Screw Clamp
2 0
LADN20
1 1 LADN11
0 2 LADN02
Spring
Terminal
2 0
LADN203
1 1 LADN113
0 2 LADN023
1
Not for
DC devices
Screw Clamp
2 0
LAD8N20
1 1 LAD8N11
0 2 LAD8N02
  4 [3]
1
Screw Clamp
4 0
LADN40
3 1 LADN31
2 2 LADN22
1 3 LADN13
0 4 LADN04
Spring
Terminal
4 0
LADN403
3 1 LADN313
2 2 LADN223
1 3 LADN133
0 4 LADN043
  4 [3]
1
Screw Clamp   2
[4]   2 [4]
LADC22
Spring
Terminal
  2
[4]   2 [4]
LADC223
Table 23.61: Instantaneous Auxiliary Contacts with Dust and Damp Protected
Contacts (for use in harsh industrial environments)
Number
of
Contacts
Maximum
Number
per Device
Contact Composition
Catalog
Number
Front Mounting
Sealed
[5]
Normal
2 1
2
LA1DX20
2 LA1DX02
2 2 LA1DY20
  4 [3]
1
2 2
LA1DZ40
2 1 1 LA1DZ31
Approvals for TeSys D IEC Style Instantaneous Control Relays
File: E164353
CCN: NKCR
File: LR43364
Class: 3211 03
For replacement AC coils, see
TeSys™ D and F Overload
Relay Accessories, page 18-22
. DC coils are not
replaceable.
[1] Add the proper voltage code from
Table 23.58 or Table 23.59 to the end of the catalog number. For example, CAD50B7.
[2] Add the proper voltage code to the end of catalog number.
[3] Auxiliary contact blocks with four contacts cannot be used on relays with low consumption coils.
[4] Includes 1 N.O. and 1 N.C. overlapping contact.
[5] Grounding terminal points (2 terminals jumpered together; see diagram on page 8 of Catalog
8501CT0101).
6/20/2017
23