Brochure

7/2
7
References
Accessories for Heavy Industrial
NEMA Style Controls 0
Separate enclosures
NEMA 1 rated (general purpose) separate enclosures
The NEMA 1 rated general purpose separate enclosures listed below, when used with open style components, are equivalent to
a standard factory-assembled control device.
For use with Type Number of poles Reference Weight
kg (lb)
Manual starters 2510 F, 2510 K All 9991 EN 1 0.2 (0.5)
2510 M (Sizes M-0 and M-1) All 9991 MG 1 1.1 (2.4)
2510 M (Size M-1P) All 9991 MG 2 0.5 (1)
Contactors 8502 SAO/SBO/SCO 2…4 9991 SCG 7 1.8 (4)
8502 SDO 2…4 9991 SDG 7 3.6 (8)
8502 SEO 2…4 9991 SEG 7 10.4 (23)
8502 SFO 2…4 9991 SFG 8 15.4 (34)
Starters 8536 SAO/SBO/SCO 2…4 9991 SCG 8 1.8 (4)
8536 SDO 2…4 9991 SDG 8 3.6 (8)
8536 SEO 2…4 9991 SEG 8 (1) 10.4 (23)
8536 SFO 2…4 9991 SFG 8 (1) 15.4 (34)
8536 SGO 3 9991 SGG 8 (1) (5) 51 (112)
Lighting contactors 8903 LO, 8903 LXO All 9991 LXG 1 (6) 3.6 (8)
8903 SMO All 9991 SCG 7 (2) 1.8 (4)
8903 SPO All 9991 SDG 7 (2) 3.6 (8)
8903 SQO All 9991 SFG 8 (2) 15.4 (34)
8903 SVO All 9991 SFG 4 16.3 (36)
Definite purpose
contactors
8910 DP 1…2 9991 DPG 1 1.1 (2.5)
8910 DPA 12/13/22/23, 2…3 9991 DPG 1 1.1 (2.5)
8910 DPA 32/33/42/43
8910 DPA 14/24/34/44, 2…4 9991 DPG 2 1.8 (4)
8910 DPA 52/53
8910 DPA 62/63 2…3 9991 DPG 3 3.6 (8)
8910 DPA 72/73/92/93, 2…3 9991 DPG 4 10.4 (23)
8910 DPA 122/123
Reversing contactors 8702 SAO/SBO/SCO All 9991 SCG 9 (3) 7.3 (16)
8702 SDO All 9991 SDG 9 (3) 10.9 (24)
Reversing starters 8736 SAO/SBO/SCO All 9991 SCG 9 7.3 (16)
8736 SDO All 9991 SDG 9 10.9 (24)
NEMA 12 rated (dust-tight and drip-tight) separate enclosures
Separate enclosures can be used with open-style devices for field assembly of enclosed controls. These enclosures, plus the open
style components, are equivalent to a factory-assembled device.
For use with Type NEMA Size or
current rating
Number of
closing plates
Reference Weight
kg (lb)
Manual starters 2510 MBO, 2510 MCO M-0, M-1, M-1P 9991 MA 1 2.3 (5)
Contactors (4) 8502 SAO/SBO/SCO 0, 1 2 9991 SCA 11 4.5 (10)
8502 SDO 2 2 9991 SDA 11 6.8 (15)
8502 SEO 3 3 9991 SEA 11 23.1 (51)
8502 SFO 4 3 9991 SFA 11 23.1 (51)
Starters 8536 SAO/SBO/SCO 0, 1 2 9991 SCA 11 4.5 (10)
8536 SDO 2 2 9991 SDA 11 6.8 (15)
8536 SEO 3 3 9991 SEA 11 (1) 23.1 (51)
8536 SFO 4 3 9991 SFA 11 (1) 23.1 (51)
Lighting contactors (4) 8903 LO, 8903 LXO 30 A 2 9991 SDA 11 6.8 (15)
8903 SMO 30 A 2 9991 SCA 11 4.5 (10)
8903 SPO 60 A 2 9991 SDA 11 6.8 (15)
8903 SQO 100 A 3 9991 SEA 11 (1) 23.1 (51)
Reversing contactors (4) 8702 SAO/SBO/SCO 0, 1 3 9991 SCA 12 9.1 (20)
8702 SDO 2 3 9991 SDA 12 11.3 (25)
Reversing starters 8736 SAO/SBO/SCO 0, 1 3 9991 SCA 12 9.1 (20)
8736 SDO 2 3 9991 SDA 12 11.3 (25)
(1) Enclosure suitable for starter with solid-state overload relays only.
(2) For electrically held contactors only.
(3) For horizontally arranged Class 8702 contactors and Class 8922 breakers, replace the reset assembly with a Class 9001
Type K51 closing plate.
(4) For contactors, replace reset assembly with an appropriate closing plate; for NEMA 12 use Class 9001 Type K51 closing plate.
(5) Series B starter enclosure.
(6) If cover-mounted control units are required, select an oversized enclosure listed on page 7/4.
9991 SCG 8
DF 531381
9991 SCA 11
DF 531382
Dimensions:
pages 7/6 and 7/7