Brochure
6/5
6
References (continued)
0
Manual Starters and Switches 0
Manual starters Class 2510
Single units Type F (continued)
Type
of operator
Number
of poles
Features Enclosure type
(2)
Specification Reference Weight
kg (lb)
Starters with handle guard/lock-off
Toggle operator
(1)
1 Standard NEMA 1 (3) Standard 2510 FG 5 0.36 (0.80)
Oversized 2510 FGJ 5 0.50 (1.11)
With red pilot light NEMA 1 (3) Standard 2510 FG 5P 0.37 (0.82)
Oversized 2510 FGJ 5P 0.52 (1.15)
2 Standard NEMA 1 (3) Standard 2510 FG 6 0.37 (0.82)
Oversized 2510 FGJ 6 0.51 (1.13)
With red pilot light NEMA 1 (3) Standard 2510 FG 6P 0.38 (0.84)
Oversized 2510 FGJ 6P 0.53 (1.17)
Duplex units Type F
One starter in duplex enclosure
Toggle operator
(1)
2 Standard NEMA 1 Standard 2510 FG 02 0.50 (1.10)
With red pilot light NEMA 1 Standard 2510 FG 02P 0.51 (1.12)
Removable key
(1)
2 With red pilot light NEMA 1 Standard 2510 FG 04P 0.51 (1.12)
Two starters in one enclosure
Toggle operator
(1)
2 for each
starter
Standard NEMA 1 Standard 2510 FG 22 0.70 (1.54)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 22 0.70 (1.54)
With red pilot light on
each starter
NEMA 1 Standard 2510 FG 22P 0.70 (1.54)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 22P 0.70 (1.54)
Standard stainless
steel flush plate
2510 FS 22P 0.70 (1.54)
Removable key
(4)
2 for each
starter
With red pilot light on
each starter
NEMA 1 Standard 2510 FG 44P 0.70 (1.54)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 44P 0.70 (1.54)
Standard stainless
steel flush plate
2510 FS 44P 0.70 (1.54)
Starters and "AUTO-OFF-HAND" selector switch (a only)
Toggle operator
(1)
1 Standard NEMA 1 Standard 2510 FG 71 0.81 (1.79)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 71 0.73 (1.61)
With red pilot light NEMA 1 Standard 2510 FG 71P 0.72 (1.59)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 71P 0.80 (1.76)
Standard stainless
steel flush plate
2510 FS 71P 0.80 (1.76)
2 Standard NEMA 1 Standard 2510 FG 72 0.80 (1.76)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 72 0.80 (1.76)
With red pilot light NEMA 1 Standard 2510 FG 72P 0.80 (1.76)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 72P 0.80 (1.76)
Standard stainless
steel flush plate
2510 FS 72P 0.80 (1.76)
Removable key
(1)
2 With red pilot light NEMA 1 Standard 2510 FG 74P 0.80 (1.76)
General purpose
flush mounting
(without pull box)
Grey flush plate 2510 FF 74P 0.80 (1.76)
Standard stainless
steel flush plate
2510 FS 74P 0.80 (1.76)
(1) One thermal unit required.
(2) NEMA 1: general purpose enclosure surface mounting.
(3) For general purpose flush mounting enclosure (without pull box), order basic starter plus separate handle guard kit, reference
is 2510 FL1.
(4) Two thermal units required.
General, characteristics:
pages 6/2 and 6/3
Dimensions:
pages 6/10 and 6/11