Brochure

4/4
4
References
0
Definite Purpose Contactors 0
Types DP and DPA Class 8910
Full-load
Amperes
Locked rotor
Amperes
Resistive
load
Amperes
Motor power ratings N/O
poles
N/C
poles
(1)
Basic reference
Add code indicating
control circuit
voltage (2)
Weight
115V
single-
phase
230V
single-
phase
230V
3-phase
460/575V
3-phase
277V 480V 575V
A A A A A hp kW hp kW hp kW hp kW kg (lb)
Compact single-pole contactors
20 100 100 80 25 1 1.1 2 1.5 ––––1 8910 DP 11 (2) 0.2 (0.5)
25 125 125 100 30 2 1.5 3 2.2 ––––1 8910 DP 21 (2) 0.2 (0.5)
30 150 150 120 40 2 1.5 3 2.2 ––––1 8910 DP 31 (2) 0.2 (0.5)
40 240 200 160 50 (3) 2 1.5 5 3.7 –––1 8910 DP 41 (2) 0.2 (0.5)
Compact 2-pole contactors
(4)
20 100 100 80 30 1 1.1 2 1.5 ––––2 8910 DP 12 (2) 0.2 (0.5)
25 125 125 100 35 2 1.5 3 2.2 ––––2 8910 DP 22 (2) 0.2 (0.5)
30 150 150 120 40 2 1.5 5 3.7 ––––2 8910 DP 32 (2) 0.2 (0.5)
40 240 200 160 50 2 1.5 5 3.7 ––––2 8910 DP 42 (2) 0.2 (0.5)
2-, 3- and 4-pole contactors
(4)
20 120 100 80 25 1 1.1 2 1.5 5 3.7 7.5 5.5 2 8910 DPA 12 (2) 0.5 (1)
3 8910 DPA 13 (2) 0.5 (1)
4 8910 DPA 14 (2) 0.6 (1.3)
25 150 125 100 35 2 1.5 3 2.2 7.5 5.5 10 7.5 2 8910 DPA 22 (2) 0.5 (1)
3 8910 DPA 23 (2) 0.5 (1)
4 8910 DPA 24 (2) 0.6 (1.3)
30 180 150 120 40 2 1.5 5 3.7 10 7.5 15 11 2 8910 DPA 32 (2) 0.5 (1)
3 8910 DPA 33 (2) 0.5 (1)
4 8910 DPA 34 (2) 0.6 (1.3)
40 240 200 160 50 3 2.2 7.5 5.5 10 7.5 20 15 2 8910 DPA 42 (2) 0.5 (1)
3 8910 DPA 43 (2) 0.5 (1)
4 8910 DPA 44 (2) 0.7 (1.5)
50 300 250 200 62 3 2.2
10 7.5 15 11 30 22 2 8910 DPA 52 (2) 0.7 (1.5)
3 8910 DPA 53 (2) 0.7 (1.5)
60 360 300 240 75 5 3.7 10 7.5 25 18.5 30 22 2 8910 DPA 62 (2) 0.7 (1.5)
3 8910 DPA 63 (2) 0.7 (1.5)
75 450 375 300 94 5 3.7 15 11 25 18.5 40 30 2 8910 DPA 72 (2) 1.6 (3.5)
3 8910 DPA 73 (2) 1.7 (3.7)
90 540 450 360 120 7.5 5.5 20 15 30 22 50 37 2 8910 DPA 92 (2) 1.4 (3)
3 8910 DPA 93 (2) 1.7 (3.7)
120 720 600 480 120 10 7.5 25 18.5 40 30 75 55 2 8910 DPA 122 (2) 2 (4.4)
3 8910 DPA 123 (2) 5.9 (13)
4-pole contactors
(4)
20 120 100 80 25 1 1.1 2 1.5 5 3.7 7.5 5.5 2 2 8910 DPA 14 (2) Y392 0.6 (1.3)
25 150 125 100 35 2 1.5 3 2.2 7.5 5.5 10 7.5 2 2 8910 DPA 24 (2) Y392 0.6 (1.3)
30 180 150 120 40 2 1.5 5 3.7 10 7.5 15 11 2 2 8910 DPA 34 (2) Y392 0.6 (1.3)
40 240 200 160 50 3 2.2 7.5 5.5 10 7.5 20 15 2 2 8910 DPA 44 (2) Y392 0.7 (1.5)
(1) N/C poles on outside. N/C poles open before N/O poles close.
(2) Standard control circuit voltage for 8910 DP/DPA:
Volts 24 110 120 208–240 220 277 440 480 550 600
50 Hz V14V02– V09– V06 (5) V07 (6)
60 Hz V14 V02 V09 V04 V06 (5) –V07 (6)
Standard control circuit voltage for 8910 DPA 122/DPA 123:
Volts 24 110 120 208 220 230–240 440 480 550 600
50 Hz V12V02– V03– V06– V07–
60 Hz V01 (7) V02 V08 V03 V06 V07
(3) 50 A resistive limited to 277V. All others rated 40 A resistive (above 277V).
(4) Above 240V, all lines must be switched.
(5) Not available for Type 8910 DP 11 to 8910 DP 31 single-pole devices.
(6) Not available for Type 8910 DP single- and 2-pole devices.
(7) Only available on Types 8910 DPA 122/DPA 123.
8910 DPA 33
531125
General:
page 4/2
Characteristics:
page 4/3
Dimensions:
pages 4/8 and 4/9