References
0
Definite Purpose Contactors 0
Types DP and DPA Class 8910
Full-load
Amperes
Locked rotor
Amperes
Resistive
load
Amperes
Motor power ratings N/O
poles
N/C
poles
(1)
Basic reference
Add code indicating
control circuit
voltage (2)
Weight
115V
single-
phase
230V
single-
phase
230V
3-phase
460/575V
3-phase
277V 480V 575V
A A A A A hp kW hp kW hp kW hp kW kg (lb)
Compact single-pole contactors
20 100 100 80 25 1 1.1 2 1.5 ––––1 – 8910 DP 11 (2) 0.2 (0.5)
25 125 125 100 30 2 1.5 3 2.2 ––––1 – 8910 DP 21 (2) 0.2 (0.5)
30 150 150 120 40 2 1.5 3 2.2 ––––1 – 8910 DP 31 (2) 0.2 (0.5)
40 240 200 160 50 (3) 2 1.5 5 3.7 ––––1 – 8910 DP 41 (2) 0.2 (0.5)
Compact 2-pole contactors
(4)
20 100 100 80 30 1 1.1 2 1.5 ––––2 – 8910 DP 12 (2) 0.2 (0.5)
25 125 125 100 35 2 1.5 3 2.2 ––––2 – 8910 DP 22 (2) 0.2 (0.5)
30 150 150 120 40 2 1.5 5 3.7 ––––2 – 8910 DP 32 (2) 0.2 (0.5)
40 240 200 160 50 2 1.5 5 3.7 ––––2 8910 DP 42 (2) 0.2 (0.5)
2-, 3- and 4-pole contactors
(4)
20 120 100 80 25 1 1.1 2 1.5 5 3.7 7.5 5.5 2 – 8910 DPA 12 (2) 0.5 (1)
3 – 8910 DPA 13 (2) 0.5 (1)
4 – 8910 DPA 14 (2) 0.6 (1.3)
25 150 125 100 35 2 1.5 3 2.2 7.5 5.5 10 7.5 2 – 8910 DPA 22 (2) 0.5 (1)
3 – 8910 DPA 23 (2) 0.5 (1)
4 – 8910 DPA 24 (2) 0.6 (1.3)
30 180 150 120 40 2 1.5 5 3.7 10 7.5 15 11 2 – 8910 DPA 32 (2) 0.5 (1)
3 – 8910 DPA 33 (2) 0.5 (1)
4 – 8910 DPA 34 (2) 0.6 (1.3)
40 240 200 160 50 3 2.2 7.5 5.5 10 7.5 20 15 2 – 8910 DPA 42 (2) 0.5 (1)
3 – 8910 DPA 43 (2) 0.5 (1)
4 – 8910 DPA 44 (2) 0.7 (1.5)
50 300 250 200 62 3 2.2
10 7.5 15 11 30 22 2 – 8910 DPA 52 (2) 0.7 (1.5)
3 – 8910 DPA 53 (2) 0.7 (1.5)
60 360 300 240 75 5 3.7 10 7.5 25 18.5 30 22 2 – 8910 DPA 62 (2) 0.7 (1.5)
3 – 8910 DPA 63 (2) 0.7 (1.5)
75 450 375 300 94 5 3.7 15 11 25 18.5 40 30 2 – 8910 DPA 72 (2) 1.6 (3.5)
3 – 8910 DPA 73 (2) 1.7 (3.7)
90 540 450 360 120 7.5 5.5 20 15 30 22 50 37 2 – 8910 DPA 92 (2) 1.4 (3)
3 – 8910 DPA 93 (2) 1.7 (3.7)
120 720 600 480 120 10 7.5 25 18.5 40 30 75 55 2 – 8910 DPA 122 (2) 2 (4.4)
3 – 8910 DPA 123 (2) 5.9 (13)
4-pole contactors
(4)
20 120 100 80 25 1 1.1 2 1.5 5 3.7 7.5 5.5 2 2 8910 DPA 14 (2) Y392 0.6 (1.3)
25 150 125 100 35 2 1.5 3 2.2 7.5 5.5 10 7.5 2 2 8910 DPA 24 (2) Y392 0.6 (1.3)
30 180 150 120 40 2 1.5 5 3.7 10 7.5 15 11 2 2 8910 DPA 34 (2) Y392 0.6 (1.3)
40 240 200 160 50 3 2.2 7.5 5.5 10 7.5 20 15 2 2 8910 DPA 44 (2) Y392 0.7 (1.5)
(1) N/C poles on outside. N/C poles open before N/O poles close.
(2) Standard control circuit voltage for 8910 DP/DPA:
Volts 24 110 120 208–240 220 277 440 480 550 600
50 Hz V14V02– – V09– V06 (5) – V07 (6) –
60 Hz V14 – V02 V09 – V04 – V06 (5) –V07 (6)
Standard control circuit voltage for 8910 DPA 122/DPA 123:
Volts 24 110 120 208 220 230–240 440 480 550 600
50 Hz V12V02– – V03– V06– V07–
60 Hz V01 (7) – V02 V08 – V03 – V06 – V07
(3) 50 A resistive limited to 277V. All others rated 40 A resistive (above 277V).
(4) Above 240V, all lines must be switched.
(5) Not available for Type 8910 DP 11 to 8910 DP 31 single-pole devices.
(6) Not available for Type 8910 DP single- and 2-pole devices.
(7) Only available on Types 8910 DPA 122/DPA 123.
8910 DPA 33
531125
General:
page 4/2
Characteristics:
page 4/3
Dimensions:
pages 4/8 and 4/9