Brochure

1/12
1
References
0
Contactors and Starters 0
Type S, NEMA-style
Variants
Variants – Operators
Description For use on Colour/Marking Suffix to the
contactor or
starter reference
(1)
Weight
Class Enclosure
type
kg (lb)
Push buttons 8502, 8536 NEMA 1, 12 "Start-Stop" A
8702, 8736 NEMA 1, 12 "Forward-Reverse-Stop" A1
"High-Low-Stop" A2
Pilot lights
without operating interlock
(2)
8502, 8536,
8702, 8736
NEMA 1 Red P1
Green P2
Amber P3
Clear P4
Push-to-test pilot lights
without operating interlock
(2)
8502, 8536,
8702, 8736
NEMA 12 Red P21
Green P22
Amber P23
Clear P24
Yellow P25
LED pilot lights 8502, 8536,
8702, 8736
NEMA 1 Red P51
Green P52
Yellow P55
Special wiring 8502, 8536,
8702, 8736
NEMA 1 Red/"Off" P71
Green/"On" P72
Selector switches 8502, 8536,
8702, 8736
NEMA 1,
NEMA 12
"Hand-Off-Auto" C
8702, 8736 NEMA 1,
NEMA 12
"On-Off" C6
"Forward-Off-Reverse" C14
"Forward-Reverse" C20
Variants – Transformers
Description For use on Functions Suffix to the
contactor or
starter reference
(1)
Weight
Class Enclosure
type
kg (lb)
Separate control circuit 8502, 8536,
8702, 8736
NEMA 1, 12 Specify voltage and frequency S
Fused control circuit
without transformer
8502, 8536,
8702, 8736
NEMA 1, 12 One fuse F
Two fuses F4
Control circuit transformers
standard capacity (50/60 Hz)
(3)
8502, 8536,
8702, 8736
NEMA 1, 12 Fuses: 2 (primary), 0 (secondary) F4T (4)
Fuses: 2 (primary), 1 (secondary) FF4T
Fuses: 1 (primary), 2 (secondary) (5) F1F10T
Fuses: 2 (primary), 2 (secondary) F4F10T
Additional capacity
(50/60 Hz) Two fuses in primary
(3)
8502, 8536,
8702, 8736
NEMA 1, 12 100 VA additional capacity F4T11 (6)
200 VA additional capacity F4T12 (6)
Additional capacity
(50/60 Hz) Two fuses in primary
and one fuse in secondary (3)
8502, 8536,
8702, 8736
NEMA 1, 12 100 VA additional capacity FF4T11
(1) Example: 8536 SAG 12 V01 A P1 P2. All suffixes are listed in alphanumeric order after the voltage code.
(2) Unless otherwise requested, the standard practice is to wire the red pilot light to indicate that the device is energized. No
additional auxiliary contact is required. Also, standard practice is to wire the green pilot light to indicate that the device is de-
energized. An additional normally closed auxiliary contact is required; please consult your regional sales office.
(3) Control circuit transformer selection table:
Primary-secondary 120-24 (7) 208-120 240-24 (7) 240-120 277-120 480-24 (7) 480-120 480-240 600-120
60 Hz V89 V84 V82 V80 V85 V83 V81 V87 V86
Example: 8536 SAG 12 V81 F4T A P1 P2.
(4) Not available with 24 V secondary on Size 3. Select appropriate transformer with secondary fuse protection. See transformer
selection table.
(5) Single phase with one leg earthed, or earthed 3-phase applications only.
(6) Not available with 24 V secondary. Select appropriate transformer with secondary fuse protection. See transformer selection
table for 24 V secondary restrictions.
(7) 24 V coils are not available on Sizes 4–7.
General, characteristics:
pages 1/4 and 1/5
Dimensions:
pages 1/14 to 1/17