Brochure

7/21
7
References
Accessories for Heavy Industrial
NEMA Style Controls 0
Compression lugs
Terminal block
Compression lugs
A Class 9999 Type AL hardware kit is required to install Versa-Crimp
®
compression lugs on Class 8903 Type S, 100 to 800 A
lighting contactors. The lugs are suitable for both copper and aluminum wire.
One VCEL lug is required for each line or load terminal. Each Class 9999 Type AL hardware kit includes mounting hardware for
3 terminals, line or load side.
Example: to install compression lugs on a 300 A 3-pole device, line and load sides, order 6 x VCEL-060-12H1 lugs and 2 x
Class 9999 Type AL 11 hardware kits.
For use with Versa-Crimp
catalogue number
Material Wire
range
(min.-max.)
Number
of poles
Reference Weight
kg (lb)
Class Type Current rating
8903 SQ 100 A VCEL-021-14S1 Al/Cu 8–1/0 (1)
SV 200 A VCEL-022-516H1 Al/Cu 1–2/0 2 poles 9999 AL 13
3 poles 9999 AL 14
4 poles 9999 AL 15
VCEL-024-516H1 Al/Cu 2/0–4/0 2 poles 9999 AL 13
3 poles 9999 AL 14
4 poles 9999 AL 15
VCEL-030-516H1 MCM Al/Cu 4–300 2 poles 9999 AL 13
3 poles 9999 AL 14
4 poles 9999 AL 15
SX 300 A VCEL-050-12H1 MCM Al/Cu 2/0–500 9999 AL 11
VCEL-060-12H1 MCM Al 400–600 9999 AL 11
MCM Cu 400–500 9999 AL 11
VCEL-075-12H1 MCM Al 500–750 9999 AL 11
MCM Cu 500 9999 AL 11
SY, SZ 400, 600 A VCEL-060-12H2 (2) MCM Al 400–600 9999 AL 12
MCM Cu 400–500 9999 AL 12
VCEL-075-12H2 (2) MCM Al 500–750 9999 AL 12
MCM Cu 500 9999 AL 12
SJ 800 A (3)
Terminal block
The terminal block provides easy wiring of a "Hand-Off-Auto" selector switch or "Start-Stop" push buttons with separate control.
The terminal block requires no panel space. It simply snaps onto Type S, Sizes 00–4 contactors and starters by two tabs and is
secured to the left-hand coil terminal.
For use with Reference Weight
kg (lb)
Class Type NEMA Size
8502, 8702, 8536, 8736 SA to SF 00 to 4 9999 T7
(1) Not required.
(2) One or two lugs may be mounted on each terminal.
(3) Compression lugs for these devices are available only as a factory modification. Order: suffix Y1574. Specify the wire size, up
to 750 MCM Al or 500 MCM Cu, and the number of terminals.
Class 8903
with compression
lugs installed
DF531389
9999 T7
DF531390