Certifications 2
Safety Data Sheet
Report No.: TCT200304M008 Page 7 of 15
Hotline: 400-6611-140 Tel: 86-755- 27673339 Fax: 86-755-27673332 http://www.tct-lab.com
Graphite
7782-42-5
TWA:1mg/m³ respirable
fraction all forms except
graphite fibers
TWA: 15 mg/m³ total dust synthetic
TWA: 5 mg/m³ respirable fraction
Synthetic
(vacated) TWA: 2.5 mg/m³
respirable dust natural
(vacated) TWA: 10 mg/m³ total dust
synthetic
(vacated) TWA: 5 mg/m³ respirable
fraction synthetic
TWA: 15 mppcf natural
IDLH: 1250 mg/m³
TWA: 2.5 mg/m³ respirable dust
Phosphate(1-),
hexafluoro-, lithium
21324-40-3
TWA:2.5mg/m³ F
TWA:2.5mg/m³ F
TWA:2.5mg/m³ dust
(vacated)TWA:2.5mg/m³
Copper
7440-50-8
TWA:0.2mg/m³ fume
TWA:1mg/m³Cu dust and mist
TWA:0.1mg/m³fume
TWA:1mg/m³dust and mist
(vacated) TWA:0.1mg/m³Cu
dust,fume,mist
IDLH:100mg/m³dust ,fume and mist
TWA:1mg/m³dust and mist
TWA:0.1mg/m³ fume
Aluminum foil
7429-90-5
TWA:1mg/m³ respirable
fraction
TWA:15mg/m³ total dust
TWA:5mg/m³respirable fraction
(vacated) TWA:15mg/m³total dust
(vacated) TWA:5mg/m³
respirable fraction(vacated)
TWA:5mg/m³ AL Aluminum
TWA:10mg/m³ total dust
TWA:5mg/m³ respirable dust
Nickel
7440-02-0
TWA:1.5mg/m³
TWA:1mg/m³
(vacated) TWA:1mg/m³
IDLH:10mg/m³
TWA:0.015mg/m³
ACGIH TLV: American Conference of Governmental Industrial Hygienists - Threshold Limit Value
OSHA PEL: Occupational Safety and Health Administration - Permissible Exposure Limits Immediately Dangerous to Life or Health
Other Exposure Guidelines
Vacated limits revoked by the Court of Appeals decision in AFL-CIO v. OSHA,
965 F.2d 962 (11th Cir., 1992) See section 15 for national exposure control
parameters
(b) Appropriate engineering controls
Engineering Measures
Showers
Eyewash stations
Ventilation systems
(c) Individual protection measures, such as personal protective equipment.
Eye/Face Protection:
None required for consumer use. If there is a Hazard of contact:. Tight sealing
safety goggles. Face protection shield.