Product Manual
1017628-C Page 22 ©2017 Spyker Spreaders/A Brinly-Hardy Co.
Troubleshooting
TROUBLESHOOTING / FREQUENTLY ASKED QUESTIONS
Problem Diagnosis Solution
Rate gate is binding and will not
open/close properly.
Rate gate is jammed
with debris.
Thoroughly wash out hopper and shut
off plates with water. Ensure debris is
not stuck between shut off plate and
rate gate plate.
- Very slightly loosen bolt 1017551 (9)
allowinglinkage1017340(7)tooat.
- Very slightly loosen screw 1001255 (8)
allowinglinkage1017340(7)tooat.
- Slide bracket 1017776 (76) to the left
or right.
There is not an even distribution
coming from the spreader.
The Accuway is not set properly.
Reference the Accuway adjustment
chart on page 16 of this manual.
Lever control is slow to open or
there is a grinding noise.
Lever Control (53) is rubbing against
the Control Lever Stop (73).
Loosen spring (49) by loosening locknut
(3). Seeg13C.
Lever control is making a
grinding noise.
Linkage (51) is rubbing against the
Guide Plate (47).
Loosen guide plate (47) and
adjust up/down.
Question Solution
What is the difference between
the Accuway and Rate Gate?
The Accuway Adjustment Screw (19) is a small black screw with a rectangular
head, located on the front of the Spreader. This screw controls the direction of
the distribution. See page 16.
The Rate Gate Dial (22) is a white circular knob on the back of the Spreader.
This dial controls the amount of distribution. See page 20.
How do I use the Accuway?
For initial setup, please reference step 17 of the assembly (on page 14) and then
calibrate your spreader. See calibration steps: pages 15-17.