Product Manual
1017628-C Page 14 ©2017 Spyker Spreaders/A Brinly-Hardy Co.
Assembly
17. Checking / Adjusting
the Accuway
Continue to rotate the ACCUWAY Adjustment
Screw (19) clockwise (Fig. 15a) until the Accuway
is out of view while looking down into the hopper
(Fig. 15b).
19
Fig. 15a
47
73
The Control Lever Stop
(73) can shift a little up or
down the length of the
handle as needed.
16. Tighten the Bolts
The center bolt that runs through the Control Lever
needs to be tightened enough to keep the Lever
secure, but also be free enough to function.
e) Move the gate control lever to CLOSED and re-
evaluate the rate gate. If it is closed, then no
further adjustment is necessary.
f) If the rate gate is still open, then repeat steps
3-5 until the gate is closed.
CLOSED (Dial Setting at 1) CLOSED (View From Above)
*Front of
Spreader
Start rotating the Accuway Adjustment Screw (19)
clockwise.
Secure the Linkage Guide (47) in place by
tightening* the bolt (46) that goes through the lower
handle. (Seestep12onpage12forclarication).
Fig. 15b
46
*Bolt can remain slightly loose, allowing Linkage Guide to move.
18. Final Step
Place the Screen
(69) down inside the
hopper.
Attach the Hopper
Cover (68) by hooking
it around the rim of
the Hopper.
69
68