Manual

P6
P7
Color Access Mode Displa y (C.A.M.D)
Specifications & Operation Dia gram
1. The C.A.M.D has one push key for adjustment and 1
Color Display Panel to display all kinds of function.
2. For "MODE" indicator, the C.A.M.D shows following
functions:
(1). SEMI: Semi Auto Mode
(2). BUR 3: Burst-3 Mode
(3). BUR 6: Burst-6 Mode
(4). AUTO: Full Auto Mode
3. For "R.O.F." display , the rate of fire can be adjusted
from "6" to "13", that is the rate of fire will be ranged
from 6 shots per second to 13 shots per second. But for
"SEMI" mode, the "R.O.F" display will be fixed on "13"
for reactive trigger response up to 13 shots per second.
4. When Power is turned ON, the defaults will be Mode
="SEMI" and "R.O.F" = "13". All settings can be
adjusted while power remain ON. Any adjustments will
be lost when Power turns OFF.
5. The Battery pattern on the panel is used for
"Battery Low" Indicator, and will stay OFF during
normal operations. When the capacity of battery
drops to about 1/3 of the battery full capacity, this
indicator will be turned ON.
Power ON
Burst 3
MODE display " BUR 3 "
ROF display unchanged
Burst 6
MODE display " BUR 6 "
ROF display unchanged
FULL AUTO
MODE display " AUTO"
ROF display unchanged
Click
Click
Click
ROF Adjustment
The Indicator of Burst-6 will be on,
and the shot rate display on the right
will start to flash. You can adjust the
shot rate by clicking Push key. The
range of rate is from 6 to 13 shots per
second.
Press
ROF Adjustment
The Indicator of FULL will be on,
and the shot rate display on the right
will start to flash. You can adjust the
shot rate by clicking Push key. The
range of rate is from 6 to 13 shots per
second.
Press
End of ROF
Adjustment
Press
7. Operation Methods:
Press, Push and hold the key for over 2 seconds,
then release the key.
Click, Push and then release the key. The duration
should be less than 1 seconds.
For SEMI Mode, the ROF
can not be adjusted.
6. The C.A.M.D is also equipped with a "LOCK" function.
A short-circuit plug located on the internal circuit board serves
this function. When this plug had been pull off, the MODE
will be locked to SEMI, and cannot be adjusted.
End of ROF
Adjustment
Press
Notes:
During the interval of ROF Adjustment, the SAFETY will be
turned ON automatically, that is, trigger will be disabled on
this interval. The SAFETY will be turned OFF automatically
at the end of ROF Adjustment, then the trigger will be
functioning normally. The SAFETY is displayed on the
lower right corner of the panel.
SEMI AUTO
MODE display " SEMI "
ROF display "13"
Click
ROF Adjustment
The Indicator of Burst-3 will be on,
and the shot rate display on the right
will start to flash. You can adjust the
shot rate by clicking Push key. The
range of rate is from 6 to 13 shots per
second.
Press
End of ROF
Adjustment
Press