Datasheet
5
Document number: DT14-08-201911-E 
Rev. & Date: V2019-1 2019.10.24 
2.7V 2000F CDCL-STZ 
5
1)
Charge and Discharge procedure (Figure 1) 
A)
Charge the capacitor using constant current I to rated voltage V
0
B)
Keep rated voltage 5 mins 
C)
Discharge the capacitor using constant current I to half rated voltage, record discharge time 
T
1
 during voltage change from V
1
to V
2
D)
Rest 2-5s, record voltage change ΔV 
E)
Discharge it to a very low voltage around 0.01V 
F)
V
1
=85% V
0
 V
2
=50% V
0
2)
Capacitance 
C=I·T1/(V1-V2) 
C: Capacitance (F) 
I: Constant Discharge Current (A)   T
1
: Discharge Time (S) 
V
1
-V
2
: Voltage Change (V) 
3)
DC ESR 
DC ESR=ΔV/I 
DC ESR: DC Equivalent Series Resistance (Ω) 
ΔV: Voltage Change (V) 
I: Constant Discharge Current (A) 
4)
AC ESR 
Measure AC ESR using LCR meter 
Frequency: 1KHz 
Voltage: fully discharge 
REMARK: SPSCAP EDLC SHOULD BE DISCHARGED WITH RESISTOR FOR AT LEAST 12 HOURS 
BEFORE MEASUREMENT OF CAPACITANCE OR ESR. 
Figure 1 