Datasheet
5
Document number: DT14-08-201911-E
Rev. & Date: V2019-1 2019.10.24
2.7V 2000F CDCL-STZ
5
1)
Charge and Discharge procedure (Figure 1)
A)
Charge the capacitor using constant current I to rated voltage V
0
B)
Keep rated voltage 5 mins
C)
Discharge the capacitor using constant current I to half rated voltage, record discharge time
T
1
during voltage change from V
1
to V
2
D)
Rest 2-5s, record voltage change ΔV
E)
Discharge it to a very low voltage around 0.01V
F)
V
1
=85% V
0
V
2
=50% V
0
2)
Capacitance
C=I·T1/(V1-V2)
C: Capacitance (F)
I: Constant Discharge Current (A) T
1
: Discharge Time (S)
V
1
-V
2
: Voltage Change (V)
3)
DC ESR
DC ESR=ΔV/I
DC ESR: DC Equivalent Series Resistance (Ω)
ΔV: Voltage Change (V)
I: Constant Discharge Current (A)
4)
AC ESR
Measure AC ESR using LCR meter
Frequency: 1KHz
Voltage: fully discharge
REMARK: SPSCAP EDLC SHOULD BE DISCHARGED WITH RESISTOR FOR AT LEAST 12 HOURS
BEFORE MEASUREMENT OF CAPACITANCE OR ESR.
Figure 1