means that Open-E iSCSI is the only system attached to this UPS and that there
is no action necessary to do remote shutdown for other systems in the network.
Single means, that Open-E iSCSI is the only system attached to this UPS and
that there is no action necessary to do remote shutdown for other systems in the
network.
Master means, that Open-E iSCSI is connected to the UPS and sends a signal
through the network to shutdown other systems in the network.
Slave means, that Open-E iSCSI is reacting on a "power down-signal" from an
UPS master.
During a power failure you cannot log into the Open-E iSCSI. Users,
who are connected to the Open-E iSCSI server during the UPS-time
continue to have full access to all files on the iSCSI target.
Function “Clock settings”
Here you define an NTP server (Network Time Protocol) to synchronize your
Open-E iSCSI with a time server on the Internet.
Time and date display are static. What is shown are the time and date
at which the setup menu was accessed.