AUTOPRIME PRODUCT OPERATORS HANDBOOK AUTOPRIME DIESEL DRIVEN PUMPSETS 8010019A 50_7514A AC50 & AC75 AC80 & AC100 100M_31A 10 0M _30A 100M & 150M SPP Pumps Ltd. Crucible Close Mushet Industrial Park Coleford Gloucestershire ENGLAND GL16 8PS Telephone: 01594 832 701 Fax: 01594 836 300 Document No: . W72-002E Revision No: .................. 12 Revision Note No: . R 39552 Date Issued .
DECLARATION OF CONFORMITY We SPP Pumps Limited Pump Model AC50 & AC75 AC80 & AC100 100M & 150M Of Crucible Close Mushet Industrial Park Coleford Gloucestershire England GL16 8PS Sound Level (dB) Measured Guaranteed LWA 105 108 106 109 103 106 Cross 2000/14/EC- Guaranteed sound power level. The conformity assessment procedure followed was in according with ANNEX V of the Directive.
Operators Handbook for Diesel Driven Pump Sets Manual No/Rev W72-002E / 11 CONTENTS 1. INTRODUCTION.................................................................................... 4 1.1 PUMP DESIGNATIONS ........................................................................................... 4 1.2 PUMP TYPES .......................................................................................................... 4 2. SAFETY PRECAUTIONS .............................................................
Manual No/Rev W72-002 / 11 Operators Handbook for Diesel Driven Pump Sets 1.INTRODUCTION The purpose of this handbook is to lay down operating guidelines and simple routine maintenance for the AUTOPRIME range of diesel engine driven mobile pump sets fitted with vacuum pumps. Instructions and statements contained within this handbook are given with our best intentions and are correct at the time of compilation. They are subject to alteration at any time. 1.
Manual No/Rev W72-002E / 11 Operators Handbook for Diesel Driven Pump Sets VACUUM UNIT PUMP LIFTER LUB OIL RESERVOIR ENGINE LUB OIL FILTER ENGINE MINI BALL VALVE DELIVERY VALVE VACUUM COVER FLANGE (in line) PUMP (on far side) PRIMARY TANK VACUUM PUMP SILENCER EXHAUST SILENCER ENGINE FUEL FILTER ENGINE STOP LEVER FUEL TANK FILLER SUCTION FLANGE STARTER MOTOR (if fitted) BATTERY (electric start only) LUB OIL DIPSTICK (on underside of filler cap) KEYSWITCH & RUNNING HOUR RECORDER (electric start onl
Manual No/Rev W72-002 / 11 Operators Handbook for Diesel Driven Pump Sets 2.SAFETY PRECAUTIONS 2.2.8 Always allow adequate ventilation for diesel engines. Be aware of fire risks from items such as exhaust pipes and silencers. Never place flammable items around the unit. 2.2.9 Collapsible hoses must not be used on the suction side of the pump. 2.1 SAFETY SYMBOLS Safety instructions within this manual are marked with the following symbols: This symbol refers to general mechanical aspects of safety.
Manual No/Rev W72-002E / 11 Operators Handbook for Diesel Driven Pump Sets 4.SERIAL NUMBER A serial number plate is attached to the unit on the side of the priming tank. This serial number must be quoted in any enquiry for spares or service. SPP Pumps Limited Reading, RG31 7SP ENGLAND Tel: ++44(0)118 932 3123 Fax: ++44(0)118 932 3302 Type Serial No. 5.1.9 Check that the discharge non return valve is seating properly and that there is no debris in the ball chamber that may prevent correct operation.
Manual No/Rev W72-002 / 11 Operators Handbook for Diesel Driven Pump Sets a) three position keyswitch (Off, 1, Start) b) protection override push button c) circuit breaker d) hours run counter e) four warning indicator lamps::Charge Oil pressure Water temperature Coalescer oil level seconds after the engine is up to speed. & 5.3AFTER STARTING The pump will prime automatically once the suction hose is submerged. If the pump fails to prime refer to the fault finding guide. 5.
Operators Handbook for Diesel Driven Pump Sets Manual No/Rev W72-002E / 11 6.PUMP MAINTENANCE CHART For engine maintenance periods refer to the engine operators handbook at the back of this publication.
Manual No/Rev W72-002 / 11 Operators Handbook for Diesel Driven Pump Sets 1. 7.MAINTENANCE INSTRUCTIONS 7.4DRIVE BELT ADJUSTMENT 7.1 COALESCER (100M, 150, 150M, & 200) Check the oil level in the coalescer tank and drain any water daily. The top of the oil should be level with the underside of the filler cap. Water is removed by means of the drain tap fitted to the side of the coalescer sump.
Manual No/Rev W72-002E / 11 Operators Handbook for Diesel Driven Pump Sets PUMP VACUUM PRESSURE SEAL The seal is product lubricated and therefore requires only regular inspections of condition, signified by rate of leakage, and eventual replacement. To replace the packing:- material is graphite impregnated braided P.T.F.E. 7. 7.5.1Close coupled AC50, AC75, AC80 & AC100 pumps 1. Ensure the volute is drained and contains no harmful residues. A drain tap is located on the bottom of the volute. 2.
Manual No/Rev W72-002 / 11 Operators Handbook for Diesel Driven Pump Sets 5. Slide the seal assembly back along the shaft to locate on backplate. Tighten securing nuts and screws evenly. 6. Refit the shaft guard. 7.6MECHANICAL SEALS ATTENTION 1. Ensure that the coolant/lubricant level is maintained. It is imperative that the seals are never run dry. Immediate seal failure will result. 2. Any contamination of the fluid should be investigated immediately.
Manual No/Rev W72-002E / 11 Operators Handbook for Diesel Driven Pump Sets Figure 7-5, Figure 7-6, Figure 7-7). Replace if distorted or damaged 1 60AFELEA 2 Figure 0-8 High capacity air filter 25 & 60 cfm units Undo the screws holding the retaining cover and remove (1) the cover to inspect the filter. The element pulls out (2). Note that the orientation of the unit should be as shown so that any debris from the filter falls away from the outlet connection when the unit is opened.
Manual No/Rev W72-002 / 11 Operators Handbook for Diesel Driven Pump Sets Figure 0-10 25 & 60cfm main valve assembly 7.12SURGE CONTROL VALVE On 25 and 60cfm priming tanks a surge control valve is fitted. This should be checked regularly for signs of wear or damage. Components arrowed in Figure 7-11 are vulnerable to wear and should be replaced if worn excessively. The valve seat should be greased to prevent seizure. Figure 0-11 Surge control valve ---“--- 60PTVLVA.
Manual No/Rev W72-002E / 11 Operators Handbook for Diesel Driven Pump Sets 8.FAULT FINDING GUIDE Disconnect suction hose Blank off suction entry Fit vacuum gauge Pump Fails to Prime NO Are all plugs tight? Rectify YES Reading between 85 - 89 .5 kpa (28.5 0 30 ft H20)? NO Is the mini ball valve open? AC 50/75 Type of unit? Check vertical suction lift YES Lift< or = 6.1m (20ft) for AC50/75 8.53m (28ft) for AC80/100 9.
Manual No/Rev W72-002 / 11 Operators Handbook for Diesel Driven Pump Sets 9.TECHNICAL DATA PUMP TYPE AC50 & AC75 3 AC80 & AC100 100M 150 150M 200 VACUUM PUMP (f /m) 6 18 25 SOLIDS HANDLING CAPABILITY (mm dia) 28 40 44 LISTER ENGINE TYPE AD1 TR1 TR2 LPW3 TS3 TR3 LPW4 CD4 FUEL TANK CAPACITY (litres) 14 69 75 69 122 130 122 APPROX. RUNNING TIME ON FULL TANK (hrs) 14 20 21 28 10 IMPELLER BACK PLATE CLEARANCE 0.50 - 1.5 mm 0.019 - 0.059" 0.30 - 0.