User's Manual
Table Of Contents
ZEN SYSTEM SPECIFICATIONS
18
Architecture
Physical
Installation
Diagnostics
Frequency Bands PCS Uplink: 1850-1910 MHz Downlink: 1930-1990 MHz
Formats Supported GSM / GPRS / EDGE / UMTS & IS-95 / CDMA / 1XRTT / 1XEVDO
Typical Coverage Area 2,500 sq. ft (230 m2)
System Gain
(fully adaptive, includes antenna)
Uplink: 0 to +70 dB maximum
Downlink: 0 to +70 dB maximum
System Stability Margin > 10 dB
Downlink Operating Range -85 to - 45 dBm
Maximum Input Level
(receive isotropic power)
Uplink: -10 dBm maximum
Downlink: -45 dBm maximum
Output Level -EIRP
(fully adaptive)
Uplink: +30 dBm maximum (composite)
Downlink: 0 dBm maximum (composite)
Third Order Intercept
(EIRP, radiated)
PCS Uplink: +50 dBm Downlink: +27 dBm
Power Consumption 20 W
Network Access Unit COVERAGE UNIT
Operating
Temperature
-40
°
to 131 F
°
(-40
°
to +55
°
C) 32
°
to +104
°
F
(0
°
to +40
°
C)
Size 7 x 10 x 2.5 in. 2.75 x 6 x 1.25 in.
Weight 5 lbs. 0.5 lb.
RF Connectors Type F: Coverage Port (weatherproof) Type F: Network Access Port
RF Cable Supports up to 60 ft RG-6 cable between Network Access & Coverage Units
Power Supply Universal power adapter (90 - 260 VAC, 47 -63 Hz)
Installation Time Less than one hour typical
Network Access (outward
facing) Unit Alignment
No prior knowledge of base station location required.
Customer’s mobile phone is used to find strongest signal.
Test Equipment None required.
No RF knowledge required for installation.
User Controls None, setup and operation is fully automatic.
User Interface Built-in power LED on Coverage Unit
Built-in system status LED on Network Access Unit