User's Manual
Digital Repeater User Manual
- 14 -
Test the call quality of donor antenna
Fix the donor antenna after selecting the best position, and adjust slightly its height or angles in
order to get the signals with suitable input power level and calling Quality.
Cable layout and connector assembly:
1) Keep the type, specifications, routing direction, location, and curvature radius of cables in compliance with
the design requirement. Place cables in good order, bend them smoothly, and protect the outer skin against
any damage.
2) Bind cables in good order when laying them on cable racks. Keep cables within cable troughs, without any
cross, when you do not bind them. When leading cables in or out of troughs, use a hole-opener to open
cable troughs and then install PVC lock-nuts to protect them.
3) Keep horizontal cables straight and fasten them stably with a fixing clip every 1 to 1.5 meters, with a proper
stress.
4) Bind and fasten vertical cables every two to three meters to avoid damaging cables or connectors owing to
their own heavy weight. Take back the cables and re-lay them when you have difficulty in pulling them, and
avoid using a strong force to pull them.
5) Separate RF cables from power cables. Take proper isolation measures if they have to be placed on the
same cable racks owing to the site condition restriction.
6) Correctly fasten all connection parts of the whole system, from the antenna to active interfaces to passive
interfaces, and keep electrical interfaces well contacted. Give waterproof treatment to outdoor connection
parts.
7) Take lightning protection measures for the antenna and feeder system in accordance with the design
Lightening
Test Engineer Phone