Extended Vertical Surface Mount
This configuration can be used to mount the DU from an
overhead vertical surface (such as a beam or truss) and
allows for full rotation either left to right or up and down,
depending on how the mount is fastened to the DU.
The second bracket required for this mounting
configuration is provided with the optional Outdoor
Mounting kit.
3.1.2 DU Outdoor Mounting
The mounting bracket has holes, keyhole slots, and rounded slots for 1/4-in lag bolts.
Mounting to a wood structure
1. Use the holes in mounting bracket as a template and mark the hole locations.
2. Drill 1/8-in. diameter holes approximately 2.5-in. deep.
3. Install the DU mounting bracket using at least two 1/4-in. lag bolts.
4. Fasten the DU to the mounting bracket.
Mounting to a brick or concrete structure:
1. Use holes in mounting bracket as a template and mark the hole locations.
2. Use a masonry drill bit to drill 5/16-in. diameter holes, 2-in. deep.
3. Insert masonry screw anchors so that the anchor is flush to the mounting surface.
4. Install the DU mounting bracket using at least two 1/4" lag bolts.