SPOTCELL 100 SYSTEM SPECIFICATIONS
32 SpotCell
A.2.2 DU Antenna Summary
Gain 10 dBi
Elevation Beamwidth 62°
Azimuth Beamwidth 50°
Front-to-Back 20 dB
Ver ti cal Pola rizatio n
A.3 Architecture
Frequency Band Uplink: 824-849 MHz
Downlink: 869-894 MHz
Complete A or B sub-bands factory set (adjacent carrier
rejection)
* Must be specified at time of order
Formats Supported AMPS, NAMPS, CDMA, TDMA
Coverage Area Fully adaptive, supports multiple simultaneous users
Up to 20,000 Sq feet (~1850 Sq Meters)
or 50,000 Sq feet in open unobstructed areas
System Gain Automatic, fully adaptive, Maximum 93dB downlink, 89
dB uplink
RF Environment Up to 147dB path loss to/from the base station
Input Overload Protection Uplink: Fully adaptive
Downlink: Fully adaptive
Maximum Output Levels
(radiated)
Uplink: Fully adaptive, up to +30 dBm EIRP (composite)
Downlink: Fully adaptive up to +9 dBm EIRP (composite)
Third Order Intercept
(radiated)
Uplink: +52 dBm EIRP
Downlink: +30 dBm EIRP
Power Supply 7.5 VDC and 10.25 VDC universal power adapter that
connects to the indoor unit, outdoor unit power is
supplied via the RF cable
Power Consumption < 22 W