4.4 DU indoor mounting
To mount the DU indoors:
1. Use the mounting bracket as a template and mark the hole
locations. Mark the two regular holes if no motion is required or
mark the hole and the slot if motion is required.
2. If the mounting is in a solid wood surface, or a stud covered by
drywall, drill a 5/32 inch diameter hole. Mount the unit with 2 inch
wood screws.
or
If the mounting is in drywall, drill a ¼ diameter hole and insert an
anchor. Mount the unit with 1/2 inch pan head screws.
3. Attach cables to the wall using tie wraps and mount directly to the
wall where possible (using 1/2 inch pan head screws). If an anchor is
required drill a 3/16 inch diameter hole, insert the anchor, and
fasten with 1/2 inch pan head screws.
4.5 Mounting the CU
The CU can be surface mounted flat or you can attach the provided ball
bracket as illustrated below. The bracket can be rotated to allow
mounting to a ceiling or wall such that the face of the unit is parallel to
the floor or ceiling, or positioned at any appropraite angle.
Figure 4.8: CU mounting bracket.
CU bracket