User's Manual

Spotwave Wireless Inc.
15
3.2 Choosing a location for the SpotCell 100 SCU (indoor unit)
The SCU should be optimized and mounted, after the DDU has been
optimized and mounted. Generally, the SCU should be mounted in a
location as far as possible from the DDU, while being within the area to
have improved coverage.
If mounted on a ceiling, the unit should be downward facing, and in the
center of the area requiring cell phone coverage.
If mounted on a wall, the unit should be positioned in the middle of the
area to be covered side-to-side, and off-centered slightly front-to-back,
approximately as shown in figure # below. It should be mounted as high
on the wall as possible.
Figure 3.9:SCU positioning on a wall.
3.2.11 Positioning the SCU
1.
Ensure that the DDU position has been optimized and has been
mounted in place.
2.
Move the switch on the SCU from ‘Install’ to ‘Active’.
3.
Hold the SCU in the position it is to be mounted. In an ideal
application, the display on the SCU will show 5 bars. If the display
is not showing 5 bars and there are alternate possible mounting
TO BE UPDATED