3.2.8 Installing the DDU
Three methods of positioning the DDU (based on location) are outlined
in the following procedure. Specifically they refer to installing inside
buildings, on external walls, and on rooftops.
1.
Position the DDU (but do not mount it) as close to the final desired
mounting location as possible. The SCU does not have to be in its
final location while positioning the DDU and it is usually helpful to
have the SCU near the DDU.
2.
Connect the DDU and SCU with the enclosed RF cable.
3.
Connect the power supply wires to the SCU by holding down the
blue tab and pushing the positive wire (marked with text) into the
positive (+) side of the connector. While still holding down the blue
tab, push the remaining negative wire (identified by no text) into
the negative (-) side of the connector. Release the tab to secure the
power supply wires.
Figure 3.1: Inserting wires in SCU to supply power
Indoors Roof External wall
While not strictly
required, it is highly
recommended the
DDU be installed
facing a window
when installed
indoors.
The SCU does not have to be in its final
position at this time, but it should not be
brought outdoors.