3.1.3 Avoid obstructions
General placement of the DDU and SCU must be in unobstructed
areas. For example, the SCU should not be placed on a wall behind any
type of furniture (behind items such as metal filing cabinets would be a
particularly poor location). Similarly for the DDU, the front of the unit
should not be directly facing any type of metal structures, which are
often found on building rooftops.
3.1.4 Proximity to power source
The indoor unit must be located within 20 feet of a power source.
3.1.5 Distance between DDU and SCU
Although you should separate the DDU and SCU as much as possible,
there are only 25 meters of cabling provided to connect the two units.
Make sure the general location of the two units is within 25 meters.
Note: An additional cable or extension, made from copper core RG6
quad shield cable, may be inserted, to a maximum of 50 meters total
length.
3.1.6 Orientation of DDU relative to SCU
If possible face the DDU and SCU in opposite directions, and back to
back. While not a requirement, some installations will perform better if
the units are positioned in this manner.
3.1.7 Barrier between DDU and SCU
The greater the physical obstruction between the DDU and SCU, the
better the performance. Dense obstructions such as brick, concrete or
metal walls are better than wooden or plaster walls.
3.2 Positioning the SpotCell 100 DDU (outward facing unit)
It may not be possible to install the DDU indoors when installing the
SpotCell 100 in remote areas. An effort should be made to install the
DDU outdoors and the DDU should be installed as high as possible
when the installation is in a remote area,