SpotSee Impact Indicator Technical Data
Activation curves for the ShockWatch Label, Clip, and Tube are based on the indicator receiving an impact at a 45° angle.
The response curves generally follow the equations below.
The ShockWatch Label is most sensitive to impacts at a 45° angle; however, there is a slight deviation in the response of a
ShockWatch Label to an impact at an angle of 90°. In most applications, this deviation is not relevant. However, there are
some applications where precise impact values at specific angles are required.
The deviation in a ShockWatch indicator’s response due to the change in angle generally follows this equation:
90° acceleration (G) value = 45° acceleration (G) value ÷ 0.7071
SHOCKWATCH LABEL RESPONSE EQUATIONS
PRODUCT EQUATION
Type 30 Label/Clip/Tube G=367.2/t + 102.5
Type 35 Label/Clip/Tube G=299.8/t + 81.5
Type 47 Label/Clip/Tube G=233.1/t + 52.7
Type 55 Label/Clip/Tube G=215.0/t + 40
Type 65 Label/Clip/Tube G=201.1/t + 25.1
Type 75 Label/Clip/Tube G=193.0/t + 17.2
Type 85 Label/Clip/Tube G=187.8/t + 10.6
Companion labels, alert stickers, and alert tape can be incorporated into an overall program for reducing product
mishandling. Contact your SpotSee Regional Manager or Local Distributor for more information.
ACCESSORIES & RELATED PRODUCTS
SpotSee is an ISO 9001-2015 company, and as the global leader in supply chain damage prevention programs, SpotSee’s
testing and inspection equipment is calibrated by an ISO/IEC accredited organization, traceable to NIST standards.
QUALITY
If you are unsure of how to use or interpret the SpotSee Impact Indicators, please contact SpotSee Technical Support by
visiting www.spotsee.io/contact-us for the latest contact information.
TECHNICAL SUPPORT