User's Manual

Table Of Contents
Page 36
SmartOne C User Manual Confidential & Proprietary Information
9100-0410-01 R2.4
OPTIONS TAB
Device Turned On Message - The SmartOne is configured to send a Device Turned On Message on Power-up
by default.
Interval for Replace Battery Message - The SmartOne can be configured to transmit a Replace Battery
message based on a low battery condition.
To turn this feature on, select the Enabled checkbox.
Configuration range extends from 0 to 45 days in steps of a day. The default is 1 day.
The SmartOne will detect low battery conditions while at least 100 more messages can still be transmitted.
Interval for Diagnostic Message - The SmartOne can send a diagnostic message with information on the
diagnostic status of the device.
To turn this feature on, select the Enabled checkbox.
The diagnostic message includes battery status, GPS average search time, GPS fails and number of
transmissions since last diagnostic message.
Transmit interval of diagnostic messages with a transmission rate from 1 to 45 days. The default is
30 days.
SmartOne Solar Only - This section is applicable to configuring SmartOne Solar devices only; refer to the
SmartOne Solar User Manual for details.