Operating Guide
GEN4000-SS Portable Gas Fuel Generator
15
Fuel Cock
The fuel cock is located between the fuel tank and carburetor. When the fuel cock is in the ON position, fuel is allowed to flow from the fuel tank to
the carburetor. Be sure to return the fuel cock to the OFF position after stopping the engine.
Choke Rod
The choke is used to provide an enriched fuel mixture when starting a cold engine. It can be opened and closed by operating the choke rod
manually. Pull the rod out toward CLOSED to enrich the mixture for cold starting
USING THE GENERATOR
• USE THIS GENERATOR ONLY OUTDOORS IN NON-CONFINED AREAS. DO NOT SECURE THE GENERATOR WITH A CHAIN OR ROPE, AS
THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY.
• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator.
After the engine has been running for several minutes, electrical devices may be connected to this generator.
AC Usage
Electrical devices running on AC current may be connected according to their wattage requirements.
Rated (Running) Wattage
3500
Surge Wattage
4000
The rated (running) wattage corresponds to the maximum wattage a generator can output on a continuous basis.
The surge wattage corresponds to the maximum amount of power a generator can output for a short time. Many electrical devices, such as a
refrigerator, require short bursts of extra power for starting and stopping fan motors, etc., in addition to their listed rated wattage. Motorized devices
typically require more than their rated wattage for startup. The surge wattage ability of a generator allows for this extra power requirement.
The total running wattage requirement of the electrical devices connected to a generator should not exceed the rated wattage of the generator itself.
To calculate the total wattage requirement of the electrical devices to be connected, look up the rated (running) wattage of each device and add
these numbers together to find the total wattage that all of the devices together will draw from the generator. If the total wattage of the selected
devices exceeds the rated wattage of the generator, DO NOT connect all of the devices. Select a combination of the electrical devices that will have
a total wattage less than or equal to the rated wattage for the generator.
This generator can run at its surge wattage capacity for only a short time. Connect electrical devices requiring a rated (running) wattage
equal to or less than the rated wattage of this generator. Never connect devices requiring a rated wattage equal to the surge wattage of a
generator.
Figure 4
The Recoil Start is located on the front of the generator.