Install Instructions

SD-214 / 052015
© 2015 Parker Hannin Corporation
Sporlan Division, Parker Hannifin Corporation
206 Lange Drive, Washington, MO 63090 USA
phone 636 239 1111 • fax 636 239 9130
www.sporlan.com
ODF and larger. The flow
passageway in the drier
shell is smaller than the
diameter of the fitting.
This is necessary to obtain
a proper gasket surface
for the internal parts. The
outlet flow passageway is
approximately the same
size as the inside diameter
of the core. The size of the
flow passageway results
in a restriction in the
larger line sizes. This is
not a problem as long
as the larger Catch-Alls
are selected according to
the recommendations in
Bulletin 40-10.
Filter-Drier Type Number
Maximum Rated Pressure
SI Units – kPa English Units – psi
C-R420 Series 4482 650
C-480, C-960, C-1440, C-19200 4482 650
C-30000 and C-40000 Series 4137 600
All replaceable core Catch-All
Filter-Driers with ODF solder
type connections are suitable
for Refrigerants 22, 123, 124,
125, 134a, 290, 401A & B,
402A & B, 404A, 407A, 407C,
407F, 410A, 507, 1234yf, and
1234ze. Do not use replace-
able core Catch-Alls (having
the aluminum end plate)
with refrigerants 40 (Methyl
Chloride) or 30 (Methylene
Chloride). Also do not use
Methyl Alcohol in any
system having a replace-
able core Catch-All with an
aluminum end plate.
The new tube construction
and optional secondary
filter installed in replace-
able core Catch-All Filter-
Driers with ODF solder type
connections cannot be used
on ammonia systems. All
replaceable core Catch-All
Filter-Driers with NPT
female connections, using
the tie rod construction, are
suitable for all of the above
listed refrigerants plus
Ammonia (R-717).
Listed by Underwriters Laboratories,
Inc. Guide Card SMGT, File No.
SA-1756 A and B; and Canadian
Standards Association File LR-19953.
See Maximum Rated Pressure data
below.
Refer to Bulletin 40-10 for
complete model range, ATEX
and additional installation,
operation, and replacement
instructions. This product is
in compliance with ATEX
directive 94/9/CE under II 3 G
TX Ta -46°C to 65°C (-50°F to
149°F).
TIE RODS
GASKET
CORE
STRAINER
OUTLET
CONNECTION
Typical Assembly
C-30013 thru C-40033-G
WARNING – USER RESPONSIBILITY
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED
ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide
product or system options for further investigation by users having technical expertise.
• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components
and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The
user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning
the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized
distributors.
• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or
specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and
sufficient for all applications and reasonably foreseeable uses of the components or systems.