Brochure

Liquid Line Inches
lb
Page 22 – Bulletin 40-10
Replaceable Core Type
Specifications
C
UL
US
Listed — Guide-SMGT-File No. SA-1756.
* “P” Dimension is the pull space required to change core.
** Optional Secondary Filter must be purchased separately. O-rings (p/n 621-025) are supplied with each secondary filter, but can be purchased separately. The secondary filter
cannot be used if the shell is installed in the suction line.
TYPE
CONNECTION
SIZE
Inches
ODF Solder
OPTIONAL
SECONDARY
FILTER **
NO. OF
CORES
OR FILTER
ELEMENTS
CORE
PART
NUMBER
VOLUME
OF
DESSICANT
Cu. In.
FILTER
ELEMENT
PART
NUMBER
MOUNTING
BRACKETS
SHELL DIMENSIONS
Inches
SHIPPING
WEIGHT
lb
A B C D E F G *P
C-R424-G
C-R425-G
C-R427-G
1/2
5/8
7/8
1 RCW-42 42 A-175-1
9.00
9.06
9.44
4.75
6.76
6.94
7.25
2.81
2.69
3.03
3.50
.50
.62
.75
6.50 6-1/2
C-R420 Series have a maximum rated pressure of 650 psi.
C-485-G
C-487-G
C-489-G
C-4811-G
C-4813-G
5/8
7/8
1-1/8
1-3/8
1-5/8
FS-480 1
RCW-48,
RCW-4864,
or
RC-4864-HH
48 RPE-48-BD A-685
9.15
9.30
9.50
9.60
9.60
6.00 5.00
5.92
6.07
6.37
6.37
6.37
3.50
3.72
3.78
3.94
3.97
4.75
.50
.75
.91
.97
1.09
7.50 12
C-967-G
C-969-G
C-9611-G
C-9613-G
7/8
1-1/8
1-3/8
1-5/8
FS-960 2 96 RPE-48-BD A-685
14.84
15.04
15.14
15.14
6.00 5.00
11.61
11.81
11.91
11.91
3.72
3.78
3.94
3.97
4.75
.75
.91
.97
1.09
13.00 16
C-1449-G
C-14411-G
C-14413-G
1-1/8
1-3/8
1-5/8
FS-1440 3 144 RPE-48-BD A-685
20.58
20.68
20.68
6.00 5.00
17.45
17.45
17.45
3.94
3.94
3.97
4.75
.97
.97
1.09
18.62 20
C-19211-G
C-19213-G
C-19217-G
1-3/8
1-5/8
2-1/8
FS-19200 4 192 RPE-48-BD A-685
26.22
26.22
26.22
6.00 5.00
22.99
22.99
22.43
3.94
3.97
4.65
4.75
.97
1.09
1.38
24.25 23
C-480 through C-19200 Series (including NPT pipe connections) have a maximum rated pressure of 650 psi.
C-30013-G
C-30017-G
1-5/8
2-1/8
3
RCW-100,
RC-10098,
or
RC-10098-HH
300 RPE-100 A-175-2
27.94
28.06
7.50 6.25
23.88
24.00
5.12
5.12
6.00
1.12
1.38
25.62
40
C-40017-G
C-40021-G
C-40025-G
C-40029-G
C-40033-G
2-1/8
2-5/8
3-1/8
3-5/8
4-1/8
4 400 RPE-100 A-175-2
34.56
34.75
34.44
34.81
35.12
7.50 6.25
30.50
30.56
29.81
30.06
29.81
5.31
5.38
5.06
5.50
5.62
6.00
1.38
1.50
1.75
2.00
2.19
32.12
47
47
47
49
49
C-30000 & C-40000 Series (including the C-40016-P) have a maximum rated pressure of 500 psi.
NPT PIPE CONNECTIONS
C-484-P
C-966-P
C-1448-P
C-19212-P
1/2
3/4
1
1-1/2
1
2
3
4
RCW-48,
RC-4864, or
RC-4864-HH
48
96
144
192
RPE-48-BD A-685
9.08
14.67
20.42
25.85
6.00 5.00
5.85
11.44
17.19
22.62
3.41
3.48
3.66
3.76
4.75
7.50
13.00
18.62
24.25
12
16
20
23
C-40016-P 2 4
RCW-100
RC-10098, or
RC-10098-HH
400 RPE-100 A-175-2 34.44 7.50 6.25 30.38 4.38 6.00 32.12 51
Type C-R424-G through C-R427-G
Type C-485-G through C-40033-G
Type C-484-P through C-40016-P
C US
LISTED
A
D
E
C
G
*P
G
F
B
Diameter
-g indicates unit is supplied with 1/4”
female pipe connection in the flange
plate and pipe plug. If the unit is
intended for liquid line service an
angle charging valve for system
charging purposes can be installed
in place of the pipe plug. If the unit is
used in the suction line for clean-up
after burnout, then insert a Schrader
type access valve to serve as a pres-
sure tap. Angle charging and Schrader
type access valves are available from
your Sporlan wholesaler. NOTE:
Catch-All shells with plain flange plate
are available as a non-catalog option
with a minimum order requirement.
-p indicates female threaded pipe
connections.
SIGNIFICANCE OF THE TYPE NUMBER SUFFIX The letters in the Catch-All type number each have a significance.