Brochure

Page 12 / Bulletin 30-10
Types B14 and E14 Series 22, 134a, 401A, 402A, 404A, 407C, 502, 507
Application
Types B14 and E14 Series are compact solenoid
valves with pilot operated disc construction for re-
frigeration and air conditioning. These valves may
be mounted horizontally, on their side or in
a vertical line. These valves are also suitable for
suction line service because very low pressure dif-
ferential, 1 psi, is required for full operation.
The Type E14 series solenoid valves feature ex-
tended solder type connections as standard. One
important benefit to the user is that all valves in the
“E14” series can be installed without disassembly
using either low or no silver content brazing alloy.
The MKC-2 and OMKC-2 coils are Class “F” tem-
perature rated and are provided as standard, therefore
a high temperature coil is not required for discharge
service.
Ordering Instructions
When ordering complete valves, specify Valve Type,
Connections, Voltage and Cycles.
When ordering Body Assembly, specify Valve Type
and Connections.
When ordering Coil Assembly ONLY, specify Coil
Type, Voltage and Cycles.
Example: MKC-2 120/50-60; OMKC-2 120/50-60.
Dimensions Inches
Specifications MKC-2 and OMKC-2 Coil
EVLAV
SEIRES
EPYT
DRADNATS
SNOITCENNOC
sehcnI
TROP
EZIS
sehcnI
DPOM
isp
SEITICAPACDIUQILLANIMON
noitaregirfeRfosnoT
SGNITARLIOC
STNAREGIRFER
22 a431 A104 A204 A404 C704 205 705
porDerusserP isp
CA CD 3 2 2 3 3 3 3 3
DRADNATS
SELCYC/STLOV
STTAW
CA CD
41B
2P41B elameFTPN2/1
61/7
003 052
8.51 0.21 9.21 4.01 4.01 5.41 2.01 2.01
06-05/42
06-05/021
06-05/042-802
06-05/042-802-021
51 81
2S41B
MDO8/7-FDO8/5
003 052
2S41BM
2S41BO 572
41E
052S41E
FDO8/5XFDO8/5
003 052
052S41EM
052S41EO 572
072S41E
FDO8/7XFDO8/7 003 052
072S41EM
Type MB14S2
Normally Closed
Type OB14S2
Normally Open
Type E14S250
Normally Closed
n
Maximum rated pressure 500 psi.
n
Dual voltage 4-wire coils, 120-208-240/50-60 are available at slight additional cost. For
other voltages and cycles, consult Sporlan, Washington, MO 63090.
n
See Pages 19 and 20 for water and steam valves.
n
Available with conduit boss or junction box at no extra charge.
n
For capacity at other pressure drops, see Pages 4 and 5.
n
For mounting holes and/or bracket information see Bulletin 30-11.
1.75 Coil
Removal
3.17
A
D
*B
C
D'
1.75 Coil
Removal
3.17
A
D
*B
C
EPYT A B*
C D 'D
GNITTIF
HTPED
41B
2P41B 14.2
65.0 82.3 26.3
2S41B 00.3 26.0 05.0
41E
052S41E 88.6 74.0 52.3 15.3 05.0
VALVE
SERIES
NORMALLY
CLOSED
NORMALLY
OPEN
*Add 1.12” for Valves with Manual Lift Stem.
ODF
ODM
E14
SERIES
B14
SERIES
1.89
Optional 1/2” Conduit Boss
and Listed
Approved