User Guide

Splitvolt, Inc. 4
LED indications
The charger is equipped with an LED panel that indicates the various
states of the product, including fault and charging status.
No. Condition Power Charge Fault 1 Fault 2
1 Initialization Flash once Flash once Flash once Flash once
2 EV Connection Ready On Off Off Off
3 Charging On Flashing Off Off
4 Charging Completed On On Off Off
5 Power Self-Test Failure On Off On On
6 Communication Failure On Off Off On
7
Overvoltage or
Undervoltage
On Off On Off
8 Grounding Failure On Off Off Flashing
9 Overcurrent On Off Flashing Off
10 Power Leakage On Off Flashing Flashing
11 Overheated On On On On
Troubleshooting
If you are having trouble, note the LEDs on your unit and consult the
table above to determine the status of your system. Then follow the
steps in the table below to resolve the problem. Check our website
(www.splitvolt.com) and contact us if you are still unable to resolve.
No. Condition Resolution
1 Initialization Normal initialization upon plug-in
2 EV Connection Ready Plug handle into EV to start charging
3 Charging Charging normally
4 Charging Completed Completed charging
5 Power Self-Test Failure
Unplug from wall power and EV, then plug both
back in
6
Communication
Failure
Unplug from wall power and EV, then plug both
back in
7
Overvoltage or
Undervoltage
Unplug from wall power and EV, then plug both
back in. If fault returns, test power source,
contact electrician.
8 Grounding Failure
Unplug from wall power and EV, then plug both
back in. If fault returns, test power source,
contact electrician.
Splitvolt, Inc. 5
No. Condition Resolution
9 Overcurrent
Unplug from wall power and EV, then plug both
back in. If fault returns, test power source,
contact electrician.
10
Power Leakage /
reduction
Unplug from wall power and EV, then plug both
back in. If fault returns, test power source, try
shorter extension, contact electrician.
11 Overheated
Unplug from wall power and EV, contact an
electrician
Need more help?
Please visit www.splitvolt.com, email info@splitvolt.com, or call (650)
209-0091 and leave a message with your contact information, product
model number and the issue you are experiencing.
Specifications
Description CGB J1-016 CGB J2-016 CGB J3-016
Maximum load 240V ~60Hz 24A AC 240V ~60Hz 40A AC
Maximum current 24A 40A
Rated power 5.8Kw 9.6Kw
Input voltage AC 88-288V 50/60Hz
Dust & water rating IP55
Warranty 1 year
Safety certifications cTUVus, CE, TUV
LEDs Power, Charge, Fault 1, Fault 2
Unit weight 7.7 lbs (3.5 kg) 9.2 lbs (4.2 kg)
Output detection
protections
Short circuit
Leakage current
Overvoltage and
undervoltage
Over and under frequency
Over current
Over and under
temperature
Ground
Lightning
Operating temperature
–25C ~ +55C
Storage temperature
–40C ~ +80C
Operating humidity 20%–85%
Cable length 16’5” (5 meters)
Package dimensions
17.7 x 4.7 x 13.4 in
(45x12x34 cm)
17.7 x 5.1 x 15.7 in
(45x13x40 cm)
Package weight 6.4 lb (2.9 kg)
Interface standards
SAE J1772
NEMA 10-30
SAE J1772
NEMA 14-30
SAE J1772
NEMA 14-50