User Manual

Phonitor 2
21
Interaural Level and Time Differences as
Related to Crossfeed Setup
The following two diagrams show, respectively (on the left), the fre-
quency response of interaural level differences and (on the right) the
interaural time difference at maximum Crossfeed value and at an Angle
of 30 degrees.
The following two diagrams show, respectively (on the left), the fre-
quency response of the interaural level difference and (on the right)
the interaural time difference, at minimal Crossfeed value and an Angle
of 30 degrees.
The black curves stand for the side of the direct sound wave front,
while the gray curves stand for the opposite side. It is clearly recog-
nizable that corrections are usually done for frequencies below 1 kHz.
You should also note that the Crossfeed control functions mainly level
dependent. Effects with respect to time differences are comparatively
slight. However, that they, too, may be altered is an indicator of interac-
tion between Crossfeed and Angle control.
Control Elements