Installation & Assembly

INSTALLATION
SAFETY INFORMATION
PRE-INSTALLATION
SUITABLE FOR WET LOCATIONS
CONSULT A QUALIFIED ELECTRICIAN TO ENSURE CORRECT BRANCH CIRCUIT CONDUCTOR.
MINIMUM 90° C SUPPLY CONDUCTORS
THIS PRODUCT MUST BE INSTALLED IN ACCORDANCE WITH THE APPLICABLE INSTALLATION CODE
BY A PERSON FAMILIAR WITH THE CONSTRUCTION AND OPERATION OF THE PRODUCT AND THE
HAZARDS INVOLVED.
PLANNING INSTALLATION
Carefully remove the fixture from the carton and check that all parts are included. Be careful
not to misplace any of the screws or parts needed for installing the fixture.
1. Standard mounting fittings
CAUTION:
Turn OFF the circuit breaker and light switch before beginning installation.
IMPORTANT WARNING
We highly recommend that all installations are made by a Licensed Electrical Contractor. We are NOT
responsible by any means for the use or misuse of the following information. We are NOT responsible in
whole or in part for any harm or damage that may or may not be caused. We reserve the right to revise the
components of any product, due to parts availability or change in ETL, CUL or UL standards without
assuming any obligation or liability to modify any products previously manufactured and without notice.
These instructions do not cover all details of variations in equipment, nor do they provide for every
possible contingency to be met . Turn off / unplug power prior to installing or servicing this fixture. BE
SURE THE POWER IS OFF! Do not operate if cover shields are damaged. After installation, the edge of wall
should be properly sealed with glue to protect fixture’s wiring from potential water or other hazards.
WARNING: Read all safety precautions and installation instructions carefully before installing or
servicing this fixture. Failure to comply with these instructions could result in a potentially fatal electric
shock and/or property damage.
To reduce the risk of electrical shock or other personal injury, ensure the power is turned OFF at the
fuse or breaker box before making any electrical connections.
For outdoor use only.
Must be connected to 100-277 volt, 60 Hz power source.
Fixture should be mounted to a grounded junction box marked for use in wet locations.
Suitable for wall mount.
NOT suitable for ground locations. Minimum of 4 feet or higher.
Utility Light should be installed by a qualified electrician or person experienced with household
wiring. The electrical system, and method of electrical connection of the fixture, must be in
accordance with the National Electrical Code and local building codes.
17”
11”
Fold Fold
hinge (1)
Feed cover board (1)
siphonium (1) (not included)
2. Arm mounting fittings
3. Wall mounting fittings
Wall mounting base (1)
(not included)
Standard mounting
Arm mounting
Wall mounting
3. Fasten the screws to fix the fixture to the wall
Use expansion bolts when affixing the fixture to regular wall or stone wall
Use self-tapping screw when affixing the fixture to tree trunk or wood block
Use expansion bolts when affixing the fixture to regular wall or stone wall
Use self-tapping screw when affixing the fixture to tree trunk or wood block
Use mounting screws(8-32) when affixing the fixture to J-Box
1 2 3
3. Affix the fixture by screws
1
2
3
hex bolts (2)
5/16-18x3/4
expansion
bolts (4)
M6x50
self-tapping
screw(4)
M6x50
wire nuts (3)
P3
wrench (1)
5/16-18x3/4
mounting screws(2)
8-32x3/4
hex bolts (2)
5/16-18x3/4
expansion
bolts (3)
M6x50
self-tapping
screw(3)
M6x50
wire nuts (3)
P3
wrench (1)
5/16-18x3/4
hex bolts (2)
5/16-18x3/4
expansion
bolts (4)
M6x50
self-tapping
screw(4)
M6x50
wire nuts (3)
P3
wrench (1)
5/16-18x3/4
EVA pad
(
1
) (not included)
Pipe bending plate (1)
Pipe bending plate (1)
21
3
INSTALLATION
ATTACH POWER SUPPLY WIRE
1. Connect the fixture ground wire (GREEN) to the ground supply wire using a wire nut .
2. Connect the BLACK fixture wire to the BLACK (Line) supply wire using the wire nuts .
3. Connect the WHITE fixture wire to the WHITE (Neutral) supply wire using the wire nuts .
NOTE:
For proper connection, place the wire nuts over the wires and twist clockwise until tight.
RECOMMENDED:
Wrap each wire nut with electrical tape (not included).
Fixture Ground Wire
(GREEN)
Wire Nuts / Connector
BLACK Fixture Wire
WHITE Fixture Wire
Ground Supply Wire
Line Supply Wire
(BLACK)
Neutral Supply Wire
(WHITE)
1. Connect AC driver cord
2. Fix wiring board screws
1. Connect AC driver cord through the arm
2. Connect the fixture to the arm and fasten the screws
1. Fix wall mounting base
2. Connect AC driver code
3.
www.evereadyledlighting.com
Toll free Number:888-883-3266
techsupport@evereadyledlighting.com
Use expansion bolts when affixing the fixture to regular wall or stone wall
Use self-tapping screw when affixing the fixture to tree trunk or wood block