User's Manual Part 2

Tech-X Flex User Guide - Firmware v06.50 Tech-X Flex
®
(NG2)
8-2
Intro
Overview
Wi-Fi
Ethernet
System
IP/Video
MoCA
RF
Specs
8.2 Channel Sweep Test
The Channel Sweep Test (available from the main RF menu) provides RF measurements for up to 12
channels on the wire, serving as a batch test of a group of channels. The results produced for each
channel are a subset of the information produced when a Single Channel Test is run. For a description
of these results, see Channel testing measurements/results on page 8-12.
8.2.1 Channel Sweep Test setup
In the test setup, each tab represents a single channel to include with the test. Tabs without data
populated are ignored. Note the following:
All channels share a common Location which determines the set of thresholds to use for flagging
test results. This field must be set in the first tab. For more information, see Thresholds on page 8-23.
In each tab, you can specify a channel either by channel number or by frequency/type. To select
channels by number, you must have an active channel guide on the unit which allows the unit to
correlate the number with a frequency and type. Otherwise, channel frequencies and types can be
specified directly. In general, the use of a guide is preferred. For more information on channel guides,
see View Channel Listings on page 8-7.
Additionally, note the following about channel selection:
The unit will reject any frequencies that are not valid according to the current EIA channel table on
the unit.
If the unit can correlate a frequency with a channel in the active channel guide (if applicable), it
will automatically select the Type and disable the input field.
Figure 8-2 Channel Sweep Test setup
Preliminary issue - Limited distribution only!