User's Manual Part 2

Tech-X Flex User Guide - Firmware v06.50 Tech-X Flex
®
(NG2)
6-56
Intro
Overview
Wi-Fi
Ethernet
System
IP/Video
MoCA
RF
Specs
Table 6-26 Packet Capture - Setup
Parameter Description
Max Test Duration Maximum length of time to run the capture, in seconds. The actual time
may be shorter if:
The maximum number of frames have been captured, or
The maximum capture file size is met (100 MBytes), or
The test is stopped while in progress.
In all cases, a capture file is still produced for the length of time that the
capture ran.
Filter Expression Optional expression to filter traffic for the capture. The expression should
use the “standard” PCAP format, described in detail at the following site:
http://www.tcpdump.org/manpages/pcap-filter.7.html
Note that this syntax may be complex and requires some expertise to
apply properly.
File Name Case-sensitive PCAP filename (minus the extension) that will appear in
the Record Manager for upload, following the capture. The PCAP
extension is appended automatically.
Store pkt Length Maximum amount of each packet (Ethernet frame) to include in the
capture, in bytes. Specify 0 (zero) to store every frame in its entirety. The
overall valid range is 0 - 1499.
Frame Count Maximum number of Ethernet frames to capture, after which the test
stops automatically, where 0 indicates no limit. The overall valid range is
0 - 65535.
Preliminary issue - Limited distribution only!